Updating The Nic Configuration File In A Linux And Vmware Environment - Fujitsu PRIMERGY RX2540 M7 Upgrade And Maintenance Manual

Table of Contents

Advertisement

Basic software procedures
Clearing the SEL using the iRMC S6 web interface
▶ Log in to the iRMC S6 web interface.
▶ Open the Logs menu.
▶ Click System Event Log to open the System Event Log page.
All events concerning the system are displayed in a table in the Event Log
Content group.
▶ Click the Clear Logs button above the table to clear the SEL.
For more information on iRMC settings, see the iRMC user guides.
Collecting logs using the Infrastructure Manager
The Infrastructure Manager can collect various logs including System Event
Log for system operation and maintainance.
Please refer to the following manuals of Infrastructure Manager for
collecting logs from ISM.
See manual "FUJITSU Software Infrastructure Manager V2.8.0 User's
Guide", section "2.5 Log Management", available at:
https://ts.fujitsu.com/support/
For Japan:
See manual "FUJITSU Software Infrastructure Manager V2.8.0 解説書",
section "2.5 ログ管理機能", available at:
https://www.fujitsu.com/jp/products/software/infrastructure-software/
infrastructure-software/serverviewism/technical/
5.3.11
Updating the NIC configuration file in a Linux and
VMware environment
In order to prevent errors caused by changing network device names (eth<x>),
it is recommended to store the MAC address (hardware address) of a network
interface card in the related NIC configuration file of the Linux/VMware OS.
When replacing a network controller or the system board with onboard LAN
controllers in a server running Linux/VMware OS, the MAC address will change
but not automatically be updated in the definition file.