Hard disk drive (HDD) / solid state disk (SSD)
Preliminary steps
▶ If applicable,
"Removing the front cover with lock" on page
▶ If the HDD module to be removed is combined into a RAID array, please
proceed as follows:
RAID level
RAID 0
RAID 1
RAID 5
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using iRMC S6
web interface.
CAUTION
All data on all HDDs in the array will be lost when deleting the RAID
array!
Be sure to back up your data before deleting a RAID array.
For more information, see the "iRMC S6 - Web Interface" user
guide.
Removing a 3.5-inch HDD module
▶ Pinch the green locking clips and open the locking lever, see
▶ Pull the HDD module out a few centimeters.
154
Procedure
CAUTION
RAID 0 provides no data redundancy.
In case of an HDD module is defect, all
data are lost!
Removing an HDD module from a RAID 1 or RAID
5 array will not result in data loss. However, the
removed drive needs to be replaced immediately
by an HDD module of the same or larger capacity.
After replacing the HDD module, RAID
rebuild will be performed as a background
process, see
rebuild" on page
Upgrade and Maintenance Manual
49.
"Performing a RAID array
108.