4.4

Technical functioning

4.4.1 Normal operation

Normal positions of the different switches and breakers when the charger is in operation (idle;
not charging):
Power Cabinet
Main switch (A): Vertical ("1")
MCB (Q17) AC power supply for ACM (B): up
RCD (Q13) control (C): up
RCD (Q12) redundant control (D): up
Depot Charge Box
SPD (F2) AC Power Supply: green
MCB (F1) AC Power Supply: up
Fuse (F3,F4) DC Precharge Circuit: not blown
SPD (F5) DC Power Circuit: green

4.4.2 Switch the charger system on/off

In case it is necessary to switch off the charger system, this can be done by turning off the
main switch (A in Power Cabinet, see section
1.
Open the front door.
2. Locate the main switch (A).
3. Turn the handle counterclockwise to the horizontal position, marked with "0".
To switch the charger back on, turn the handle clockwise to the vertical position, marked with
"1". After about a minute the indicator light (beacon) will turn green.

4.4.3 Switch the depot box

In case it is necessary to switch off the depot box, this can be done by turning off the main
switch:
1.
Open the front door.
2. Locate the main switch (B).
3. Move the MCB switch down (OFF position). Green painting on the switch should be
visible
Document: v0.6 / Document No.: 6AGA000008-0102-EN | Date: 22-05-2019
Switching off the charger does not switch off Depot Box. Each box has its own
power supply. To turn off the Depot Box see chapter 4.4.3
Operating the main switch is quite arduous. Use both hands if needed and be
careful not to injure yourself.
Component overview Power Cabinet
WARNING
NOTICE
on page 18):