Sign In
Upload
Manuals
Brands
Endress+Hauser Manuals
Measuring Instruments
Proline Promass E 100
Endress+Hauser Proline Promass E 100 Manuals
Manuals and User Guides for Endress+Hauser Proline Promass E 100. We have
5
Endress+Hauser Proline Promass E 100 manuals available for free PDF download: Operating Instructions Manual, Manual
Endress+Hauser Proline Promass E 100 Operating Instructions Manual (142 pages)
Coriolis Flowmeter EtherNet/IP
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
3
About this Document
6
Document Function
6
Symbols
6
Safety Symbols
6
Electrical Symbols
6
Tool Symbols
6
Symbols for Certain Types of Information
7
Symbols in Graphics
7
Documentation
7
Registered Trademarks
8
Safety Instructions
9
Requirements for the Personnel
9
Intended Use
9
Workplace Safety
10
Operational Safety
10
Product Safety
10
Security
11
Product Description
12
Product Design
12
Device Version with Ethernet/Ip Communication Protocol
12
Incoming Acceptance and Product
13
Identification
13
Incoming Acceptance
13
Product Identification
13
Transmitter Nameplate
14
Sensor Nameplate
14
Symbols on the Device
15
Storage and Transport
16
Storage Conditions
16
Transporting the Product
16
Measuring Devices Without Lifting Lugs
16
Measuring Devices with Lifting Lugs
17
Transporting with a Fork Lift
17
Packaging Disposal
17
Installation
18
Installation Requirements
18
Installation Position
18
Environmental and Process Requirements
20
Thermal Insulation
20
Special Installation Instructions
22
Hygienic Compatibility
22
Installing the Measuring Instrument
23
Required Tools
23
Preparing the Measuring Instrument
23
Mounting the Measuring Device
23
Post-Installation Check
24
Electrical Connection
25
Electrical Safety
25
Connecting Requirements
25
Required Tools
25
Requirements for Connecting Cable
25
Terminal Assignment
26
Pin Assignment, Device Plug
27
Preparing the Measuring Device
27
Connecting the Measuring Instrument
27
Connecting the Transmitter
28
Potential Equalization
29
Requirements
29
Special Connection Instructions
30
Connection Examples
30
Hardware Settings
30
Setting the Device Address
30
Ensuring the Degree of Protection
31
Post-Connection Check
32
Operation Options
33
Overview of Operation Options
33
Structure and Function of the Operating Menu
34
Structure of the Operating Menu
34
Operating Philosophy
35
Displaying the Measured Values Via the Local Display (Optionally Available)
36
Operational Display
36
User Roles and Related Access Authorization
37
Access to Operating Menu Via Web Browser
38
Function Range
38
Prerequisites
38
Connecting the Device
40
Starting the Web Browser
40
Logging on
41
User Interface
42
Function Row
42
Disabling the Web Server
43
Logging out
43
Access to the Operating Menu Via the Operating Tool
44
Connecting the Operating Tool
44
Fieldcare
45
Establishing a Connection
45
Devicecare
46
System Integration
47
Overview of Device Description Files
47
Current Version Data for the Device
47
Operating Tools
47
Overview of System Files
47
Integrating the Measuring Device in the System
48
Cyclic Data Transmission
48
Block Model
48
Input and Output Groups
48
Commissioning
52
Post-Mounting and Post-Connection Check
52
Configuring the Device Address Via Software
52
Ethernet Network and Web Server
52
Setting the Operating Language
52
Configuring the Measuring Instrument
52
Defining the Tag Name
53
Setting the System Units
53
Parameter Overview with Brief Description
54
Selecting and Setting the Medium
56
Configuring the Communication Interface
57
Configuring the Low Flow Cut off
59
Configuring Partially Filled Pipe
60
Using the Parameter to Enter the Access Code
61
Advanced Settings
61
Calculated Process Variables
61
Carrying out a Sensor Adjustment
63
Density Adjustment
63
Configuring the Totalizer
67
Using Parameters for Device Administration
68
Simulation
68
Protecting Settings from Unauthorized Access
69
Write Protection Via Access Code
69
Write Protection Via Write Protection Switch
70
Operation
71
Read out and Modify Current Ethernet Settings
71
Reading the Device Locking Status
71
Adjusting the Operating Language
72
Configuring the Display
72
Reading off Measured Values
72
Measured Variables" Submenu
72
Endress+Hauser
73
Totalizer" Submenu
82
Adapting the Measuring Device to the Process Conditions
83
Performing a Totalizer Reset
83
Function Scope of "Control Totalizer" Parameter
85
Function Range of "Reset All Totalizers" Parameter
85
Diagnostics and Troubleshooting
86
General Troubleshooting
86
Diagnostic Information Via Leds
87
Transmitter
87
Diagnostic Information in the Web Browser
88
Diagnostic Options
88
Calling up Remedy Information
89
Diagnostic Information in Fieldcare or
89
Diagnostic Options
89
Calling up Remedy Information
90
Diagnostic Information Via Communication Interface
91
Reading out Diagnostic Information
91
Adapting the Diagnostic Information
91
Adapting the Diagnostic Behavior
91
Overview of Diagnostic Information
91
Diagnostic of Sensor
92
Diagnostic of Electronic
93
Diagnostic of Configuration
96
Diagnostic of Process
98
Pending Diagnostic Events
102
Parameter Overview with Brief Description
102
Diagnostics List
103
12.10 Event Logbook
103
12.10.1 Reading out the Event Logbook
103
12.10.2 Filtering the Event Logbook
103
12.10.3 Overview of Information Events
104
12.11 Resetting the Measuring Device
105
12.11.1 Function Range of "Device Reset" Parameter
105
12.12 Device Information
105
12.13 Firmware History
107
Maintenance
108
Maintenance Work
108
Exterior Cleaning
108
Internal Cleaning
108
Measuring and Test Equipment
108
Endress+Hauser Services
108
Repair
109
General Notes
109
Repair and Conversion Concept
109
Notes for Repair and Conversion
109
Spare Parts
109
Endress+Hauser Services
109
Return
109
Disposal
110
Removing the Measuring Device
110
Disposing of the Measuring Device
110
Accessories
111
Device-Specific Accessories
111
For the Sensor
111
Communication-Specific Accessories
111
Service-Specific Accessories
112
System Components
113
Technical Data
114
Application
114
Function and System Design
114
Input
115
Direct Measured Variables
115
Output
116
Power Supply
120
Performance Characteristics
121
Maximum Measurement Error
121
Accuracy of Outputs
122
Influence of Medium Temperature
123
Mounting
124
Mounting Requirements
124
Environment
124
Process
125
Flow Limit
126
16.10 Mechanical Construction
128
Measuring Tubes
129
Process Connections
130
16.11 Operability
131
Display Element
131
16.12 Certificates and Approvals
133
Pharmaceutical Compatibility
134
16.13 Application Packages
135
16.14 Accessories
136
16.15 Supplementary Documentation
136
Technical Information
136
Safety Instructions
137
Special Documentation
137
Installation Instructions
137
Index
138
Advertisement
Endress+Hauser Proline Promass E 100 Operating Instructions Manual (108 pages)
Coriolis flowmeter Modbus RS485
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
3
About this Document
5
Document Function
5
Symbols
5
Safety Symbols
5
Electrical Symbols
5
Tool Symbols
5
Symbols for Certain Types of Information
6
Symbols in Graphics
6
Documentation
6
Standard Documentation
7
Supplementary Device-Dependent Documentation
7
Registered Trademarks
7
Safety Instructions
8
Requirements for the Personnel
8
Designated Use
8
Workplace Safety
9
Operational Safety
9
Product Safety
10
Security
10
Product Description
11
Product Design
11
Device Version with Modbus RS485 Communication Protocol
11
Incoming Acceptance and Product
12
Identification
12
Incoming Acceptance
12
Product Identification
12
Transmitter Nameplate
13
Sensor Nameplate
13
Promass 100 Safety Barrier Nameplate
15
Symbols on Measuring Device
15
Storage and Transport
16
Storage Conditions
16
Transporting the Product
16
Measuring Devices Without Lifting Lugs
16
Measuring Devices with Lifting Lugs
17
Transporting with a Fork Lift
17
Packaging Disposal
17
Installation
18
Installation Conditions
18
Mounting Position
18
Environmental and Process Requirements
20
Special Mounting Instructions
21
Mounting the Measuring Device
22
Required Tools
22
Preparing the Measuring Device
23
Mounting the Measuring Device
23
Post-Installation Check
23
Electrical Connection
24
Electrical Safety
24
Connection Conditions
24
Required Tools
24
Requirements for Connecting Cable
24
Terminal Assignment
25
Pin Assignment, Device Plug
28
Shielding and Grounding
29
Preparing the Measuring Device
29
Connecting the Measuring Device
29
Connecting the Transmitter
30
Connecting the Safety Barrier Promass 100
31
Ensuring Potential Equalization
32
Special Connection Instructions
32
Connection Examples
32
Hardware Settings
33
Enabling the Terminating Resistor
33
Ensuring the Degree of Protection
34
Post-Connection Check
34
Operation Options
36
Overview of Operating Options
36
Structure and Function of the Operating Menu
37
Structure of the Operating Menu
37
Operating Philosophy
38
Displaying the Measured Values Via the Local Display (Optionally Available)
38
Operational Display
38
User Roles and Related Access Authorization
40
Access to the Operating Menu Via the Operating Tool
41
Connecting the Operating Tool
41
Fieldcare
41
Devicecare
43
System Integration
44
Overview of Device Description Files
44
Current Version Data for the Device
44
Operating Tools
44
Modbus RS485 Information
44
Function Codes
44
Register Information
45
Response Time
45
Data Types
45
Byte Transmission Sequence
46
Modbus Data Map
47
Commissioning
49
Function Check
49
Establishing a Connection Via Fieldcare
49
Configuring the Measuring Device
49
Setting the System Units
49
Selecting and Setting the Medium
52
Interface
53
Configuring the Low Flow Cut off
55
Configuring the Partial Filled Pipe
56
Advanced Settings
57
Defining the Tag Name
57
Calculated Values
57
Carrying out a Sensor Adjustment
58
Configuring the Totalizer
59
Simulation
60
Parameter Overview with Brief
61
Description
61
Protecting Settings from Unauthorized Access
61
Write Protection Via Write Protection
61
Switch
61
Operation
63
Read Device Locking Status
63
Reading Measured Values
63
Process Variables
63
Totalizer
64
Adapting the Measuring Device to the Process
65
Conditions
65
Performing a Totalizer Reset
65
Diagnostics and Troubleshooting
67
General Troubleshooting
67
Diagnostic Information Via Light Emitting
67
Diodes
67
Transmitter
67
Safety Barrier Promass 100
68
Diagnostic Information in Fieldcare
68
Diagnostic Options
68
Calling up Remedy Information
69
Diagnostic Information Via Communication
69
Interface
69
Reading out Diagnostic Information
69
Configuring Error Response Mode
70
Adapting the Diagnostic Information
70
Adapting the Diagnostic Behavior
70
Overview of Diagnostic Information
71
Pending Diagnostic Events
73
Diagnostic List
73
Event Logbook
74
Event History
74
Filtering the Event Logbook
74
Overview of Information Events
74
12.10 Resetting the Measuring Device
75
12.11 Device Information
75
12.12 Firmware History
76
Maintenance
77
Maintenance Tasks
77
Exterior Cleaning
77
Interior Cleaning
77
Measuring and Test Equipment
77
Endress+Hauser Services
77
Repair
78
General Notes
78
Repair and Conversion Concept
78
Notes for Repair and Conversion
78
Spare Parts
78
Endress+Hauser Services
78
Return
78
Disposal
79
Removing the Measuring Device
79
Disposing of the Measuring Device
79
Accessories
80
Device-Specific Accessories
80
For the Sensor
80
Communication-Specific Accessories
80
Service-Specific Accessories
81
System Components
81
Technical Data
82
Application
82
Function and System Design
82
Input
83
Output
84
Power Supply
86
Performance Characteristics
87
Installation
91
Environment
91
Process
92
16.10 Mechanical Construction
95
16.11 Human Interface
97
16.12 Certificates and Approvals
98
16.13 Application Packages
100
16.14 Accessories
101
16.15 Supplementary Documentation
101
Index
103
Endress+Hauser Proline Promass E 100 Operating Instructions Manual (104 pages)
EtherNet/IP Coriolis Mass Flow Measuring System
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
Table of Contents
3
Document Information
5
Document Function
5
Symbols Used
5
Safety Symbols
5
Electrical Symbols
5
Tool Symbols
5
Symbols for Certain Types of Information
6
Symbols in Graphics
6
Documentation
6
Standard Documentation
7
Supplementary Device-Dependent
7
Documentation
7
Basic Safety Instructions
8
Requirements for the Personnel
8
Designated Use
8
Workplace Safety
9
Operational Safety
9
Product Safety
9
Product Description
10
Product Design
10
Registered Trademarks
10
Incoming Acceptance and Product
11
Identification
11
Incoming Acceptance
11
Product Identification
12
Transmitter Nameplate
12
Sensor Nameplate
13
Symbols on Measuring Device
14
Storage and Transport
15
Storage Conditions
15
Transporting the Product
15
Packaging Disposal
16
Mounting
17
Mounting Requirements
17
Mounting Position
17
Requirements from Environment and Process
19
Special Mounting Instructions
20
Mounting the Measuring Device
21
Required Tools
21
Preparing the Measuring Device
21
Post-Mounting Check
22
Electrical Connection
23
Connection Conditions
23
Required Tools
23
Requirements for Connecting Cable
23
Terminal Assignment
24
Pin Assignment, Device Plug
24
Preparing the Measuring Device
24
Connecting the Measuring Device
25
Connecting the Transmitter
25
Hardware Settings
26
Setting the Device Address
26
Ensuring the Degree of Protection
27
Post-Connection Check
28
Operation Options
29
Overview of Operation Options
29
Structure and Function of the Operating Menu
30
Structure of the Operating Menu
30
Operating Philosophy
31
Access to the Operating Menu Via the Web Browser
31
Function Range
31
Prerequisites
32
Establishing a Connection
32
Logging on
33
User Interface
33
Disabling the Web Server
34
Logging out
34
Access to the Operating Menu Via the Operating Tool
35
Connecting the Operating Tool
35
Fieldcare
36
System Integration
38
Overview of Device Description Files
38
Current Version Data for the Device
38
Operating Tools
38
Overview of System Files
38
Integrating the Measuring Device in the System
38
Commissioning
39
Function Check
39
Configuring the Device Address Via Software
39
Configuring the Measuring Device
39
Setting the System Units
39
Selecting and Setting the Medium
42
Configuring Communication Interface
43
Configuring the Low Flow Cut off
45
Configuring the Partial Filled Pipe Detection
46
Advanced Settings
47
Defining the Tag Name
47
Calculated Process Variables
47
Carrying out a Sensor Adjustment
48
Configuring the Totalizer
49
Simulation
50
Protecting Settings from Unauthorized Access
51
Write Protection Via Access Code
51
Write Protection Via Write Protection Switch
51
Operation
53
Read out and Modify Current Ethernet Settings
53
Read Device Locking Status
53
Reading Measured Values
54
Process Variables
54
Totalizer
55
Adapting the Measuring Device to the Process Conditions
56
Performing a Totalizer Reset
56
Diagnostics and Troubleshooting
58
General Troubleshooting
58
Diagnostic Information Via Light Emitting Diodes
59
Transmitter
59
Diagnostic Information in the Web Browser
60
Diagnostic Options
60
Calling up Remedy Information
61
Diagnostic Information in Fieldcare
61
Diagnostic Options
61
Calling up Remedy Information
62
Diagnostic Information Via Communication
62
Interface
62
Reading out Diagnostic Information
62
Adapting the Diagnostic Information
62
Adapting the Diagnostic Behavior
62
Overview of Diagnostic Information
63
Pending Diagnostic Events
65
Diagnostic List
66
12.10 Event Logbook
66
1Event History
66
2Filtering the Event Logbook
67
3Overview of Information Events
67
12.11 Resetting the Measuring Device
67
12.12 Device Information
68
12.13 Disposal
69
1Removing the Measuring Device
69
2Disposing of the Measuring Device
70
Repair
71
General Notes
71
Spare Parts
71
Endress+Hauser Services
71
Maintenance
72
Maintenance Tasks
72
Exterior Cleaning
72
Interior Cleaning
72
Measuring and Test Equipment
72
Endress+Hauser Services
72
Return
73
Disposal
74
Removing the Measuring Device
74
Disposing of the Measuring Device
74
Technical Data
75
Application
75
Function and System Design
75
Input
75
Output
76
Power Supply
79
Performance Characteristics
80
Installation
83
Environment
83
Process
83
17.10 Mechanical Construction
84
17.11 Operability
86
17.12 Certificates and Approvals
87
17.13 Accessories
88
17.14 Documentation
88
Appendix
89
Overview of the Operating Menu
89
Index
99
Advertisement
Endress+Hauser Proline Promass E 100 Operating Instructions Manual (127 pages)
Coriolis Flowmeter Modbus RS485
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 3 MB
Table of Contents
About this Document
6
Document Function
6
Symbols for Certain Types of Information
7
Symbols in Graphics
7
Registered Trademarks
8
Safety Instructions
9
Requirements for the Personnel
9
Intended Use
9
Workplace Safety
10
Operational Safety
10
Product Safety
10
Product Description
12
Product Design
12
Incoming Acceptance and Product Identification
13
Transmitter Nameplate
14
Sensor Nameplate
15
Symbols on the Device
16
Storage and Transport
17
Storage Conditions
17
Transporting the Product
17
Measuring Devices with Lifting Lugs
18
Transporting with a Fork Lift
18
Packaging Disposal
18
Installation Requirements
19
Installation Position
19
Thermal Insulation
21
Special Mounting Instructions
23
Post-Installation Check
25
Electrical Connection
27
Electrical Safety
27
Terminal Assignment
28
Pin Assignment, Device Plug
31
Supply Voltage
31
Signal Transmission
31
Connecting the Transmitter
33
Potential Equalization
35
Special Connection Instructions
35
Connection Examples
35
Hardware Settings
36
Ensuring the Degree of Protection
37
Post-Connection Check
37
Overview of Operation Options
39
Structure and Function of the Operating Menu
40
Operating Philosophy
41
Operational Display
41
User Roles and Related Access Authorization
43
Access to the Operating Menu Via the Operating Tool
44
User Interface
45
Device Care
45
System Integration
46
Register Information
47
Modbus Data Map
49
Scan List Configuration
49
Connecting Via Fieldcare
51
Setting the Operating Language
51
Parameter Overview with Brief Description
52
Setting the System Units
52
Selecting and Setting the Medium
55
Configuring the Low Flow Cut off
58
Advanced Settings
60
Carrying out a Sensor Adjustment
62
Density Adjustment
62
Configuring the Totalizer
66
Using Parameters for Device Administration
67
Protecting Settings from Unauthorized Access
68
Write Protection Via Write Protection Switch
68
Operation
70
Endress+Hauser
71
"Totalizer" Submenu
79
Adapting the Measuring Device to the Process Conditions
80
Performing a Totalizer Reset
80
Function Scope of "Control Totalizer" Parameter
82
Diagnostics and Troubleshooting
84
General Troubleshooting
84
Diagnostic Options
86
Calling up Remedy Information
87
Reading out Diagnostic Information
87
Configuring Error Response Mode
87
Adapting the Diagnostic Information
88
Adapting the Diagnostic Behavior
88
Overview of Diagnostic Information
88
Pending Diagnostic Events
90
Diagnostics List
91
Reading out the Event Logbook
91
Filtering the Event Logbook
92
Overview of Information Events
92
Resetting the Measuring Device
93
Device Information
94
Firmware History
95
Maintenance Work
96
Exterior Cleaning
96
Measuring and Test Equipment
96
Endress+Hauser Services
96
General Notes
97
Spare Parts
97
Removing the Measuring Device
98
Disposing of the Measuring Device
98
Device-Specific Accessories
99
For the Sensor
99
Communication-Specific Accessories
99
Service-Specific Accessories
100
System Components
100
Technical Data
101
Function and System Design
101
Direct Measured Variables
102
Light Emitting Diodes (LED)
104
Protocol-Specific Data
104
Power Supply
104
Performance Characteristics
106
Reference Operating Conditions
106
Design Fundamentals
106
Zero Point Stability
107
Flow Values
107
Accuracy of Outputs
107
Pressure-Temperature Ratings
111
Flow Limit
112
Mechanical Construction
113
Certificates and Approvals
115
Application Packages
117
Heartbeat Monitoring
118
Supplementary Documentation
119
Technical Information
119
Special Documentation
120
Installation Instructions
120
Endress+Hauser Proline Promass E 100 Manual (90 pages)
Coriolis flowmeter
Brand:
Endress+Hauser
| Category:
Measuring Instruments
| Size: 7 MB
Table of Contents
Technical Information
1
Table of Contents
2
About this Document
4
Symbols Used
4
Function and System Design
5
Measuring Principle
5
Measuring System
5
Equipment Architecture
7
Safety
7
Input
8
Measured Variable
8
Measuring Range
8
Operable Flow Range
9
Output
9
Output Signal
9
Signal on Alarm
10
Ex Connection Data
12
Low Flow Cut off
13
Protocol-Specific Data
13
Power Supply
23
Terminal Assignment
23
Pin Assignment, Device Plug
30
Power Consumption
33
Current Consumption
33
Power Supply Failure
33
Electrical Connection
34
Potential Equalization
39
Cable Entries
39
Cable Specification
39
Performance Characteristics
41
Reference Operating Conditions
41
Maximum Measured Error
41
Repeatability
43
Response Time
43
Influence of Ambient Temperature
43
Influence of Medium Temperature
43
Influence of Medium Pressure
44
Design Fundamentals
44
Installation
45
Mounting Location
45
Orientation
46
Inlet and Outlet Runs
47
Special Mounting Instructions
47
Mounting Safety Barrier Promass 100
48
Environment
48
Ambient Temperature Range
48
Storage Temperature
48
Climate Class
48
Degree of Protection
48
Vibration Resistance
48
Shock Resistance
48
Impact Resistance
48
Interior Cleaning
49
Electromagnetic Compatibility (EMC)
49
Process
49
Medium Temperature Range
49
Density
49
Pressure-Temperature Curves
50
Secondary Containment
53
Rupture Disk
53
Flow Limit
53
Pressure Loss
53
System Pressure
53
Thermal Insulation
54
Heating
54
Vibrations
54
Mechanical Construction
55
Dimensions in si Units
55
Dimensions in US Units
68
Weight
76
Materials
76
Process Connections
78
Surface Roughness
78
Operability
78
Operating Concept
78
Local Display
79
Remote Operation
79
Service Interface
81
Certificates and Approvals
83
CE Mark
83
C-Tick Symbol
83
Ex Approval
84
Sanitary Compatibility
84
HART Certification
84
Certification PROFIBUS
84
Certification PROFINET
85
Ethernet/Ip Certification
85
Modbus RS485 Certification
85
Pressure Equipment Directive
85
Other Standards and Guidelines
85
Ordering Information
86
Application Packages
86
Heartbeat Technology
86
Concentration
87
Accessories
87
Device-Specific Accessories
87
Communication-Specific Accessories
87
Service-Specific Accessories
88
System Components
88
Supplementary Documentation
89
Standard Documentation
89
Supplementary Device-Dependent Documentation
89
Registered Trademarks
90
Advertisement
Related Products
Endress+Hauser Proline Prosonic Flow E 100 HART
Endress+Hauser Proline Promass E 200
Endress+Hauser eco-graph
Endress+Hauser Analytik Jena multi EA 4000
Endress+Hauser Liquiline To Go Ex CYM291
Endress+Hauser Proline Promass E TB2 HART
Endress+Hauser Proline Promass E 300 HART
Endress+Hauser Proline Promass E 500 PROFINET
Endress+Hauser Proline Promass E 300
Endress+Hauser Endress+Hauser
Endress+Hauser Categories
Measuring Instruments
Transmitter
Radar
Switch
Accessories
More Endress+Hauser Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL