Proline Promass H 300 PROFINET
Diagnostic information
No.
537 Configuration
Measured variable status
Quality
Quality substatus
Coding (hex)
Status signal
Diagnostic behavior
Influenced measured variables
–
Diagnostic information
No.
594 Relay output simulation
Measured variable status
Quality
Quality substatus
Coding (hex)
Status signal
Diagnostic behavior
Influenced measured variables
–
Diagnostic information
No.
803 Current loop
Measured variable status
Quality
Quality substatus
Coding (hex)
Status signal
Diagnostic behavior
Influenced measured variables
–
Endress+Hauser
Short text
Good
Ok
0x80 to 0x83
F
Warning
Short text
Good
Ok
0x80 to 0x83
C
Warning
12.7.4
Diagnostic of process
Short text
Good
Ok
0x80 to 0x83
F
Alarm
Remedy instructions
1. Check IP addresses in network
2. Change IP address
Remedy instructions
Deactivate simulation switch output
Remedy instructions
1. Check wiring
2. Change I/O module
Diagnostics and troubleshooting