  • Page 1 ® R&S FSV-K8 Firmware Option Bluetooth Measurements Operating Manual (;ÚÚ:2) 1176.7610.02 ─ 02...
  • Page 2 This manual describes the following R&S®FSV options: ● R&S FSV-K8 (1310.8155.02) This manual describes the following R&S ® FSV models with firmware version 2.20 and higher: ● R&S ® FSV 4 (1321.3008K04) ● ® R&S FSV 7 (1321.3008K07) ● ®...
  • Page 3: Table Of Contents

    Softkeys of the MEAS CONFIG menu............... 49 Softkeys of the Amplitude Menu (Bluetooth Mode)..........49 Softkeys of the Bandwidth Menu (option R&S FSV-K8).......... 53 Softkeys of the Frequency Menu (option R&S FSV-K8).......... 55 Softkeys of the Sweep Menu (Bluetooth mode)............56 Softkeys of the Trigger Menu (Option R&S FSV-K8)..........
  • Page 4 ® Contents R&S FSV-K8 FORMat subsystem....................109 INITiate subsystem....................109 INPut subsystem....................... 110 INSTrument Subsystem (BLUETOOTH, K8)............112 SENSe Subsystem (BLUETOOTH, K8)..............112 SENSe:ADEMod Subsystem (BLUETOOTH, K8)............119 4.10 SENSe:DDEMod Subsystem (BLUETOOTH, K8)............120 4.11 SYSTem subsystem....................123 4.12 TRACe subsystem....................124 4.13 TRIGger subsystem....................
  • Page 5: Preface

    ® Preface R&S FSV-K8 Documentation Overview 1 Preface 1.1 Documentation Overview The user documentation for the R&S FSV is divided as follows: ● Quick Start Guide ● Operating Manuals for base unit and options ● Service Manual ● Online Help ●...
  • Page 6 ® Preface R&S FSV-K8 Documentation Overview In the individual option manuals, the specific instrument functions of the option are described in detail. For additional information on default settings and parameters, refer to the data sheets. Basic information on operating the R&S FSV is not included in the option manuals.
  • Page 7: Conventions Used In The Documentation

    ® Preface R&S FSV-K8 Conventions Used in the Documentation led on the R&S FSV by default, and is also available as an executable .chm file on the CD delivered with the instrument. Release Notes The release notes describe the installation of the firmware, new and modified func- tions, eliminated problems, and last minute changes to the documentation.
  • Page 8: How To Use The Help System

    ® Preface R&S FSV-K8 How to Use the Help System 1.3 How to Use the Help System Calling context-sensitive and general help ► To display the general help dialog box, press the HELP key on the front panel. The help dialog box "View" tab is displayed. A topic containing information about the current menu or the currently opened dialog box and its function is displayed.
  • Page 9: Notes For Users Of R&S Fsv 1307.9002Kxx Models

    ® Preface R&S FSV-K8 Notes for Users of R&S FSV 1307.9002Kxx Models 2. Enter the first characters of the topic you are interested in. The entries starting with these characters are displayed. 3. Change the focus by pressing the ENTER key.
  • Page 10: Introduction To Bluetooth Measurements (K8)

    Bluetooth Overview 2 Introduction to Bluetooth Measurements (K8) Overview of Firmware Option R&S FSV-K8 This section contains all information required for operation of an R&S FSV equipped with Application Firmware R&S FSV–K8. It covers operation via menus and the remote control commands for bluetooth measurements.
  • Page 11 ® Introduction to Bluetooth Measurements (K8) R&S FSV-K8 Bluetooth Overview Bluetooth technical parameters Table 2-1: Common Parameters frequency bands 2402 + (0...78) MHz channel spacing 1 MHz symbol rate 1 Msym/s slot length 625 (sec (frequency hopping) packet sizes 1, 3, 5 slot packets...
  • Page 12: Supported Tests

    ® Introduction to Bluetooth Measurements (K8) R&S FSV-K8 Supported Tests access code 72 bits 4 bits preamble 64 bits sync word 4 bits trailer 54 bits header 240 / 1496 / 2744 bits payload*) *) During EUT evaluation the payload contains certain bit sequences: PRBS9 (Pseudo Random Bit Sequence) or 11110000 or 10101010.
  • Page 13: Overview Of Transmitter Tests

    ® Introduction to Bluetooth Measurements (K8) R&S FSV-K8 Overview of Transmitter Tests 2.3 Overview of Transmitter Tests Table 2-4: Basic Rate Measurements Output Power TX Output Spec- Modulation Char- Initial Carrier Fre- Carrier Frequency trum – Adjacent acteristics quency Tolerance...
  • Page 14: Functional Description - Block Diagram

    ® Introduction to Bluetooth Measurements (K8) R&S FSV-K8 Functional Description – Block Diagram EDR Relative TX EDR Carrier Fre- EDR Differential EDR In–band Spu- Power quency Stability Phase Encoding rious Emissions and Modulation Accuracy Trigger – – – extern/ IF power...
  • Page 15: Bandwidths

    ® Introduction to Bluetooth Measurements (K8) R&S FSV-K8 Bandwidths ture stability by sampling the IF signal and converting it digitally down into the base band (I/Q area). The measurements are performed by passing the following signal processing steps: ● LAP (Lower Address Part) trigger detection ●...
  • Page 16: Measurement Filter (Meas Filter On)

    ® Introduction to Bluetooth Measurements (K8) R&S FSV-K8 Measurement Filter (Meas Filter On) 2.6 Measurement Filter (Meas Filter On) The RF Specification allows high distortion power in the first adjacent channels. The 3 MHz filter does not suppress this kind of distortion, which leads to a high interference in modulation.
  • Page 17 ® Introduction to Bluetooth Measurements (K8) R&S FSV-K8 Oversampling Digital bandwidth Points per Symbol Sampling rate (flat area) 10 MHz 32 MHz 8 MHz 16 MHz 5 MHz 8 MHz 3.0 MHz 4 MHz 1.6 MHz 2 MHz According to the RF Test Specification an oversampling factor of 4 is required at mini- mum.
  • Page 18: Determining Average Or Max/Min Values

    ® Introduction to Bluetooth Measurements (K8) R&S FSV-K8 Determining Average or Max/Min Values 2.8 Determining Average or Max/Min Values These functions are very useful in order to obtain more stable results or to find spora- dic spurious signals not included in every burst. In many cases the RF Test Specifica- tion defines measurements over a 10 burst period.
  • Page 19: Trigger Concepts

    ® Introduction to Bluetooth Measurements (K8) R&S FSV-K8 Trigger Concepts ● The trace functions affect complete measurement curves: A resulting curve is cal- culated from several subsequent sweeps. The method of calculation (Average, Maxhold, Minhold) can be selected here as well.
  • Page 20: Instrument Functions For Bluetooth Measurements (K8)

    If the "Bluetooth" mode is already active, press the MENU key. The "Bluetooth" menu is displayed. Menu and softkey description The following softkey menus are specific to the R&S FSV-K8 option and are described here: ● chapter 3.3, "Softkeys of the Bluetooth Menu", on page 34...
  • Page 21 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 ● RBW (the IF bandwidth set up for modulation measurements is valid for all meas- urements) ● ● RBW auto mode ● VBW auto mode ● trace mode ● detector ●...
  • Page 22: Measurement Types And Result Display

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Measurement Types and Result Display 3.1 Measurement Types and Result Display The Bluetooth Measurements option provides various measurement types. The meas- urements and the corresponding result display are described in the following chapters.
  • Page 23 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Measurement Types and Result Display Fig. 3-2: Output power measurement The peak value is determined from the complete contents of the measurement trace, whereas the average power is calculated from an area of at least 20% to 80% of the burst.
  • Page 24 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Measurement Types and Result Display Result Summary The results of the measurement are summarized in a table beneath the diagram. The summary contains the following results: ● Packet type ● Packet length ●...
  • Page 25 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Measurement Types and Result Display with M = Transmit channel of the equipment under test, N = adjacent channel to be measured A violation of these limits is indicated on the screen by red color and an asterisk (*).
  • Page 26 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Measurement Types and Result Display Fig. 3-4: Modulation Characteristics measurement Result Summary The results of the measurement are summarized in a table beneath the diagram. The summary contains the following results:...
  • Page 27 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Measurement Types and Result Display fication the calculation of the carrier offset is performed from the middle of the first pre- amble bit to the middle of the bit following the preamble.
  • Page 28 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Measurement Types and Result Display With "Clear/Write" trace mode and single sweep operation the selected number of sweeps is processed and, according to the RF Test Specification, the results of all sweeps are compared with the defined tolerance.
  • Page 29 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Measurement Types and Result Display power of the GFSK and DPSK modulated parts of the signal and calculates the ratio of those values. The measurement results must conform to the requirement: ●...
  • Page 30 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Measurement Types and Result Display signals within the used frequency band lies below the required level. The analyzer records the signal only in those parts of the signal in which the instrument transmits DPSK–modulated data.
  • Page 31 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Measurement Types and Result Display 3.1.8 Carrier Frequency Stability and Modulation Accuracy (EDR) mea- surement The measurement of the Carrier Frequency Stability and Modulation Accuracy (Carr Freq Stability softkey) is an enhanced data rate measurement (EDR). It verifies that the modulation accuracy and the frequency stability are within the required limits.
  • Page 32 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Measurement Types and Result Display Label Description Freq.Error/Block Minimum, maximum and average frequency error per block Total Freq. Error Minimum, maximum and average frequency error per block + initial frequency error...
  • Page 33: Adapting The Settings To The Characteristics Of The Dut

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Adapting the settings to the characteristics of the DUT Result Summary The results of the measurement are summarized in a table beneath the diagram. The summary contains the following results: ●...
  • Page 34: Softkeys Of The Bluetooth Menu

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu 7. Configure measurement time, measurement control and the number of measure- ment cycles by pressing the corresponding softkeys. For further information refer to chapter 3.8, "Softkeys of the Sweep Menu (Bluetooth mode)", on page 56.
  • Page 35: Standard

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu └ Channel......................43 └ Meas Setup.....................44 └ Find Sync......................44 └ Zoom (Modulation Char, Init Carr Freq Tol, Carr Freq Drift)......44 Rel TX Power........................ 44 └ Channel......................44 └...
  • Page 36: Channel

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu Channel ← Output Power Opens an edit dialog box to enter the transmission channel number. From the number of the channel the center frequency is calculated in accordance to the RF Test Specifi- cation.
  • Page 37: Packet Bytes Sco

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu Packet Bytes SCO ← Meas Setup ← Output Power Defines the number of payload bytes that are transmitted in a packet. For SCO pack- ets, the payload length must be adjusted because those packets have no payload header.
  • Page 38: Find Sync On/Off

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu The LAP is used to calculate the 64–bit sync word. The sync word in return is used to determine the start of a packet by correlation and to determine the position of the first preamble bit p0 using the method described in the RF Test Specification.
  • Page 39: Burst Offset

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu If the Find Sync On/Off softkey is not activated and no burst is identified, the message "BURST NOT FOUND" is displayed, and the corresponding bit in the STATus:QUEStionable:SYNC register is set during remote operation.
  • Page 40: Search Len Manual

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu Search Len Manual ← Find Sync ← Output Power Opens an edit dialog box to enter the search length used for determining the sync word or the burst. The unit of the search length is seconds; the values range from 100 μs to (400001 / points per symbol) μs.
  • Page 41: Channel

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu Channel ← TX Spec ACLR Opens an edit dialog box to enter the transmission channel number. From the number of the channel the center frequency is calculated in accordance to the RF Test Specifi- cation.
  • Page 42: Channel

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu Channel ← Modulation Char Opens an edit dialog box to enter the transmission channel number. From the number of the channel the center frequency is calculated in accordance to the RF Test Specifi- cation.
  • Page 43: Init Carr Freq Tol

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu Init Carr Freq Tol Opens a submenu to configure the Init Carr Freq Tol measurement. For further details refer to chapter 3.1.4, "Initial Carrier Frequency Tolerance Measurement", on page 26.
  • Page 44: Meas Setup

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu Principally, setting the channel number has the same effect as changing the center fre- quency. The major difference is that the center frequency is not limited to available fre- quency band values, i.e.
  • Page 45: Find

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu Find Sync ← Rel TX Power Opens a dialog box to set the signal processing functions of the analyzer, see "Find Sync" on page 37. Settings ← Rel TX Power Opens a dialog box to define the start and stop times for power measurements.
  • Page 46: Spurious Emissions

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu The abbreviation DPSK stands for "Differential Phase Shift Keying". Remote command: on page 100 CONFigure:​ B TOoth:​ R TPower:​ D AVerage:​ S TOP​ Spurious Emissions Opens a submenu to configure the Spurious Emissions measurement. For further details refer to chapter 3.1.7, "In–band Spurious Emissions (EDR)
  • Page 47: Gate Delay (Spurious Emissions)

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu The measurement of the adjacent channels is limited to the available Bluetooth fre- quency band, which means that at maximum 79 channels (23 channels in France) will be measured.
  • Page 48: Meas Setup

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bluetooth Menu Principally, setting the channel number has the same effect as changing the center fre- quency. The major difference is that the center frequency is not limited to available fre- quency band values, i.e.
  • Page 49: Softkeys Of The Meas Config Menu

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the MEAS CONFIG menu 3.4 Softkeys of the MEAS CONFIG menu The MEAS CONFIG key provides direct access to the submenu of the currently selected measurement type. For a description of the submenus, see the corresponding keys in chapter 3.3, "Softkeys of the Bluetooth...
  • Page 50 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Amplitude Menu (Bluetooth Mode) Range Log 100 dB ← Range Sets the level display range to 100 dB. Remote command: Logarithmic scaling: DISP:WIND:TRAC:Y:SPAC LOG, see DISPlay[:​ W INDow<n>]:​ T RACe<t>:​ Y :​...
  • Page 51 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Amplitude Menu (Bluetooth Mode) Range Log 1 dB ← Range Sets the level display range to 1 dB. Remote command: Logarithmic scaling: DISP:WIND:TRAC:Y:SPAC LOG, see DISPlay[:​ W INDow<n>]:​ T RACe<t>:​ Y :​...
  • Page 52 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Amplitude Menu (Bluetooth Mode) This function is not available for input from the R&S Digital I/Q Interface (option R&S FSV-B17). Remote command: INPut:​ G AIN:​ S TATe ​...
  • Page 53: Softkeys Of The Bandwidth Menu (Option R&S Fsv-K8)

    112 INPut:​ I MPedance​ 3.6 Softkeys of the Bandwidth Menu (option R&S FSV-K8) The following section describes all softkeys available in the "Bandwidth" menu in Blue- tooth mode (BW key). It is possible that your instrument configuration does not provide all softkeys.
  • Page 54 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Bandwidth Menu (option R&S FSV-K8) Video BW Manual (TX Spec ACLR)................54 Video BW Auto (TX Spec ACLR, Spurious Emissions)..........55 Filter Type (Output Power, TX Spec ACLR, Spurious Emissions, Rel TX Power)..55...
  • Page 55: Softkeys Of The Frequency Menu (Option R&S Fsv-K8)

    120 [SENSe:​ ] DDEMod:​ F ILTer:​ M EASurement​ 3.7 Softkeys of the Frequency Menu (option R&S FSV-K8) The following table shows all softkeys available in the "Frequency" menu in Bluetooth mode (FREQ key). It is possible that your instrument configuration does not provide all softkeys.
  • Page 56: Softkeys Of The Sweep Menu (Bluetooth Mode)

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Sweep Menu (Bluetooth mode) Center Opens an edit dialog box to change the center frequency. If the frequency channel was set via the "Channel" softkey (see "Channel" on page 36), you can change the center frequency, but the relation to the frequency channel will be lost, which means that the value range for the center frequency is not limited to frequencies within valid frequency channels.
  • Page 57 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Sweep Menu (Bluetooth mode) Meas Time Manual Opens an edit dialog box to enter the measurement time. The valid value range is 1 μs to (400001 / points per symbol) μs.
  • Page 58 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Sweep Menu (Bluetooth mode) No. of ACP Chan (TX Spec ACLR, Spurious Emissions) Opens an edit dialog box to enter the number of adjacent channels, for which the power is to be measured.
  • Page 59 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Sweep Menu (Bluetooth mode) The abbreviation GFSK stands for "Gaussian Frequency Shift Keying". Remote command: on page 101 CONFigure:​ B TOoth:​ R TPower:​ G AVerage:​ S TARt​ GFSK Stop ← Settings Defines the stop time for the power measurement of the GFSK sections of the packet.
  • Page 60: Softkeys Of The Trigger Menu (Option R&S Fsv-K8)

    FSV-K8 Softkeys of the Trigger Menu (Option R&S FSV-K8) 3.9 Softkeys of the Trigger Menu (Option R&S FSV-K8) The following table shows all softkeys available in the "Trigger" menu in Bluetooth mode (TRIG key). It is possible that your instrument configuration does not provide all softkeys.
  • Page 61 R&S FSV-K8 Softkeys of the Trigger Menu (Option R&S FSV-K8) (-24dBm + RF Att ) ≤ Triggerlevel ≤ (+5dBm + RF Att), max. 30 dBm, for Preamp = (-40dBm + RF Att ) ≤ Triggerlevel ≤ (-11dBm + RF Att), max. 30 dBm, for Preamp = with 500 MHz ≤...
  • Page 62 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Trigger Menu (Option R&S FSV-K8) ● Trg/Gate Polarity ● Trigger Hysteresis ● Trigger Holdoff Note: For R&S power sensors, the "Gate Mode" Lvl is not supported. The signal sent by these sensors merely reflects the instant the level is first exceeded, rather than a time period.
  • Page 63 Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Softkeys of the Trigger Menu (Option R&S FSV-K8) Trg/Gate Polarity Sets the polarity of the trigger/gate source. The sweep starts after a positive or negative edge of the trigger signal. The default set- ting is "Pos".
  • Page 64: Further Information

    ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Further Information This softkey is only available if "IFPower", "RF Power" or "BBPower" is the selected trigger source. Remote command: on page 125 TRIGger<n>[:​ S EQuence]:​ I FPower:​ H OLDoff​ 3.10 Further Information ●...
  • Page 65 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Further Information Table 3-2: Filter types Filter Bandwidth Filter Type Application 100 Hz CFILter 200 Hz CFILter 300 Hz CFILter 500 Hz CFILter 1 kHz CFILter 1.5 kHz CFILter 2 kHz CFILter 2.4 kHz...
  • Page 66 ® Instrument Functions for Bluetooth Measurements (K8) R&S FSV-K8 Further Information Filter Bandwidth Filter Type Application 100 kHz CFILter 150 kHz CFILter FM Radio 192 kHz CFILter 200 kHz CFILter 300 kHz CFILter 500 kHz CFILter J.83 (8-VSB DVB, USA)
  • Page 67: Remote Commands For Bluetooth Measurements (K8)

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem 4 Remote Commands for Bluetooth Measure- ments (K8) This chapter describes the remote commands specific to Bluetooth measurements and those required for the described programming examples. For a description of the basic settings commands, see the base unit description.
  • Page 68: Calculate:Btooth:aclr[:List]

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem 4.1.1 CALCulate:BTOoth Subsystem (BLUETOOTH, K8) ................68 CALCulate<n>:BTOoth:ACLR[:LIST]? ................69 CALCulate<n>:BTOoth:ACLR:EXCeptions? ..............70 CALCulate<n>:BTOoth:CFDRift[:MAXimum]? ................70 CALCulate<n>:BTOoth:CFDRift:RATE? ..............71 CALCulate<n>:BTOoth:CFSTability:COUNt? ............. 71 CALCulate<n>:BTOoth:CFSTability:DEVM:[RMS]? ............... 72 CALCulate<n>:BTOoth:CFSTability:DEVM:DPCT ............72 CALCulate<n>:BTOoth:CFSTability:DEVM:D99Pct? ..............72 CALCulate<n>:BTOoth:CFSTability:DEVM:PEAK? ............
  • Page 69: Calculate:Btooth:aclr:exceptions

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Return values: <Result> <TX channel – n>...<TX channel – 1> <TX channel> <TX chan- nel + 1>...<TX channel + n> The results are returned as a list of power values.
  • Page 70: Calculate:Btooth:cfdrift[:Maximum]

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Manual operation: "TX Spec ACLR" on page 40 CALCulate<n>:BTOoth:CFDRift[:MAXimum]? This command determines the maximum Carrier Frequency Drift. Note: This command is only available with active Carrier Frequency Drift measurement (see on page 96).
  • Page 71: Calculate:Btooth:cfstability:count

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Manual operation: "Carr Freq Drift" on page 43 CALCulate<n>:BTOoth:CFSTability:COUNt? This command reads the number of measured blocks during or after a measurement. Note: This command is only available with active Carrier Frequency Stability and Modulation Accuracy measurement (see on page 96).
  • Page 72: Calculate:Btooth:cfstability:devm:dpct

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Example: For the first steps refer to chapter 4.14, "Programming Exam- ple", on page 127 CONF:BTO:MEAS CFST Activates the Carrier Frequency Stability and Modulation Accu- racy measurement. INIT;*WAI Starts the measurement with synchronization.
  • Page 73: Calculate:Btooth:cfstability:ferror:[Total]

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem This command is only available with active Carrier Frequency Stability and Modulation Accuracy measurement (see on page 96). CONFigure:​ B TOoth:​ M EASurement​ With all other measurements this command causes a query error.
  • Page 74: Calculate:Btooth:cfstability:ferror:block

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Manual operation: "Carr Freq Stability" on page 47 CALCulate<n>:BTOoth:CFSTability:FERRor:BLOCk? <Mode> This command reads the maximum frequency deviation of all blocks in the Carrier Fre- quency Stability and Modulation Accuracy measurement.
  • Page 75: Calculate:Btooth:dpencoding:[Total]

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Example: For the first steps refer to chapter 4.14, "Programming Exam- ple", on page 127 CONF:BTO:MEAS CFST Activates the Carrier Frequency Stability and Modulation Accu- racy measurement. INIT;*WAI Starts the measurement with synchronization.
  • Page 76: Calculate:Btooth:dpencoding:nerror

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem This command is only available with active Differential Phase Encoding measurement (see on page 96). With all other measure- CONFigure:​ B TOoth:​ M EASurement​ ments this command causes a query error.
  • Page 77: Calculate:Btooth:ibsemissions:exceptions

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Note: This command is only available with active In–band Spurious Emissions measurement (see on page 96). With all other measure- CONFigure:​ B TOoth:​ M EASurement​ ments this command causes a query error.
  • Page 78: Calculate:Btooth:ibsemissions:hadjacent

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Manual operation: "Spurious Emissions" on page 46 CALCulate<n>:BTOoth:IBSemissions:HADJacent? <Band> This command reads the maximum power of the upper or lower frequency band (500 kHz) of the TX channel in the In–band Spurious Emissions measurement.
  • Page 79: Calculate:Btooth:icftolerance

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Example: For the first steps refer to chapter 4.14, "Programming Exam- ple", on page 127 CONF:BTO:MEAS IBS Activates the In–band Spurious Emissions measurement. CONF:BTO:CHAN 7 Adjust the TX channel number.
  • Page 80: Calculate:Btooth:mchar:df:Maximum

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Note: This command is only available with active Modulation Characteristics measurement (see on page 96). With all other measure- CONFigure:​ B TOoth:​ M EASurement​ ments this command causes a query error.
  • Page 81: Calculate:Btooth:mchar:df2:Percent

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem <Delta> 1 | 2 the frequency deviation and the bit pattern: 1 = Δf1 : 11110000 2 = Δf2 : 10101010 Parameters: <Mode> MINimum | MAXimum | AVERage *RST:...
  • Page 82: Calculate:Btooth:mchar:ratio

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Example: For the first steps refer to chapter 4.14, "Programming Exam- ple", on page 127 CONF:BTO:MEAS MCH Activates the Modulation Characteristics measurement. CONF:BTO:SWE:COUN 20 Initiates the sweep counter with 20.
  • Page 83: Calculate:Btooth:opower[:Peak]

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Mode: Manual operation: "Modulation Char" on page 41 CALCulate<n>:BTOoth:OPOWer[:PEAK]? This command reads the peak value of the Output Power measurement according to the BLUETOOTH standard. Note: This command is only available with active Output Power measurement (see on page 96).
  • Page 84: Calculate:Btooth:plength

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Parameters: <Mode> MINimum | MAXimum | AVERage *RST: Example: For the first steps refer to chapter 4.14, "Programming Exam- ple", on page 127 CONF:BTO:MEAS OPOW Activates the Output Power measurement.
  • Page 85: Calculate:Btooth:ptype

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem CALCulate<n>:BTOoth:PTYPe? This command determines the type of the packet analyzed by a preceding measure- ment. Note: This command is only available if a measurement was started via INITiate<n>[:​ before and if this measurement is completed. With a missing or incom- IMMediate]​...
  • Page 86: Calculate:Btooth:rtpower:gfsk

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Parameters: <Mode> MINimum | MAXimum | AVERage *RST: Example: For the first steps refer to chapter 4.14, "Programming Exam- ple", on page 127 CONF:BTO:MEAS RTP Activates the Relative Transmit Power measurement.
  • Page 87: Calculate:Btooth:rtpower:ratio

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Mode: Manual operation: "Rel TX Power" on page 44 CALCulate<n>:BTOoth:RTPower:RATio? <Mode> This command reads the ratio of the transmission power for the GFSK and DPSK mod- ulation in the Relative Transmission Power measurement (PDPSK/PGFSK). With a sweep count 1, the command returns the current value, irrespective of the parameter.
  • Page 88 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Return values: <Result> PASS FAIL Example: INST:SEL BTO Activates the Bluetooth Measurements option INIT:CONT OFF Selects single sweep operation CONF:BTO:MEAS OPOW Activates Output Power measurement INIT;*WAI Starts the measurement with synchronization...
  • Page 89 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Parameter, measuring function or result display Output unit CARRIER FREQUENCY STABILITY (R&S FSV–K8) – – DIFF PHASE ENCODING (R&S FSV–K8) Suffix: <n> Selects the measurement window. <m> Selects the marker.
  • Page 90 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CALCulate subsystem Parameters: <Excursion> The peak excursion is the distance to a trace maximum that must be attained before a new maximum is recognized, or the distance to a trace minimum that must be attained before a new...
  • Page 91: Configure:btooth Subsystem (Bluetooth, K8)

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) Parameters: <Unit> DBM | V | A | W | DBPW | WATT | DBUV | DBMV | VOLT | DBUA | AMPere *RST: Example: CALC:UNIT:POW DBM Sets the power unit to dBm.
  • Page 92: Configure:btooth:bandwidth|Bwidth[:Resolution]

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) Parameters: <NoChannels> 1 to 78 *RST: Example: CONF:BTO:ACLR:ACP 10 Selects 10 adjacent channel pairs. Mode: Manual operation: "No. of ACP Chan (TX Spec ACLR, Spurious Emissions)" on page 41 CONFigure:BTOoth:BANDwidth|BWIDth[:RESolution] <Bandwidth>...
  • Page 93: Configure:btooth:bandwidth|Bwidth:video

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) The settings for the measurements of Modulation Characteristics, Initial Carrier Fre- quency Tolerance, and Carrier Frequency Drift are common to all three measure- ments.For all other Bluetooth measurements the setting is only valid for the currently active measurement (see on page 96).
  • Page 94: Configure:btooth:cfstability:bcount

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) Note: This setting is only valid for the currently active measurement (see CONFigure:​ on page 96) and it is independent of the other Bluetooth BTOoth:​ M EASurement​...
  • Page 95: Configure:btooth:detector<1

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) Manual operation: "Channel" on page 36 CONFigure:BTOoth:DETector<1...4>[:FUNCtion] <Detector> This command selects the detector for the currently selected Bluetooth measurement. The numeric suffix assigns the detector to a trace (1 to 4).
  • Page 96: Configure:btooth:ibsemissions:gate:auto Once

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) Parameters: <NoChannels> 1 to 78 *RST: Example: CONF:BTO:IBS:ACP 20 Selects 20 adjacent channel pairs. Mode: Manual operation: "No. of ACP Chan (TX Spec ACLR, Spurious Emissions)" on page 41 CONFigure:BTOoth:IBSemissions:GATE:AUTO ONCE This command adjusts the gate settings for the In–band Spurious Emissions automati-...
  • Page 97 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) Parameters: <MeasType> OPOWer Output Power measurement, see chapter 3.1.1, "Output Power Measurement", on page 22 ACLR Adjacent Channel Power measurement, see chapter 3.1.2, "Adjacent Channel Power Measurement", on page 24...
  • Page 98: Configure:btooth:pbsco

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) CONFigure:BTOoth:PBSCo <NoBytes> This command selects the number of payload bytes that are transmitted in a packet. Parameters: <NoBytes> 1 – 1000 *RST: Example: CONF:BTO:PBSC 50 Selects the number of payload bytes.
  • Page 99: Configure:btooth:power:average:stop

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) Example: CONF:BTO:POW:AVER:STAR 10PCT Sets the starting point for the calculation to 10% of the burst length. Mode: Manual operation: "Power Avg Start (Output Power)" on page 40 CONFigure:BTOoth:POWer:AVERage:STOP <Position>...
  • Page 100: Configure:btooth:ptype

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) CONFigure:BTOoth:PTYPe <Type> This command selects the packet type to be measured. Parameters: <Type> 1 slot packet 3 slot packet 5 slot packet AUTO automatic selection of the packet type...
  • Page 101: Configure:btooth:rtpower:gaverage:start

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) Parameters: <Time> 0 to 100% *RST: Example: CONF:BTO:RTP:DAV:STOP 80 Sets the stop time for the power measurement of the DPSK sec- tions of the packet. Mode: Manual operation: "DPSK Stop"...
  • Page 102: Configure:btooth:sweep:count

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) CONFigure:BTOoth:SWEep:COUNt <NoSweeps> This command defines the number of sweeps for the currently selected Bluetooth mea- surement. This number will be started as a "single sweep". With trace mode setting...
  • Page 103: Configure:btooth:sweep:time

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) CONFigure:BTOoth:SWEep:TIME <Duration> This command defines the duration of a sweep sequence for the active Bluetooth mea- surement. Parameters: <Duration> 1us to [130560us / (points per symbol)] *RST:...
  • Page 104: Configure:btooth:trace:Select

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 CONFigure:BTOoth Subsystem (BLUETOOTH, K8) The number of measurement to be executed for AVERage, MAXHold and MINHold is defined with the on page 102 command. Please CONFigure:​ B TOoth:​ S WEep:​ C OUNt​...
  • Page 105: Display Subsystem (Bluetooth, K8)

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 DISPlay Subsystem (BLUETOOTH, K8) 4.3 DISPlay Subsystem (BLUETOOTH, K8) ...............105 DISPlay[:WINDow<n>]:TRACe<t>[:STATe] ..............105 DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe] ............106 DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:MODE ............ 106 DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:PDIVision ............107 DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RLEVel ........... 107 DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RLEVel:OFFSet ........... 107 DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RPOSition ............108 DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RVALue ..............
  • Page 106 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 DISPlay Subsystem (BLUETOOTH, K8) Manual operation: "Range Log Manual" on page 49 "Range Log 100 dB" on page 50 "Range Log 50 dB" on page 50 "Range Log 10 dB" on page 50 "Range Log 5 dB"...
  • Page 107 This command defines the position of the reference level on the display grid.. When using a tracking generator (only with option R&S FSV-B9 or -B10, requires active normalization), and in Bluetooth mode (option R&S FSV-K8) this command defines the position of the reference value for all windows.
  • Page 108 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 DISPlay Subsystem (BLUETOOTH, K8) Parameters: <Position> 0 PCT corresponds to the lower display border, 100% corre- sponds to the upper display border. Range: 0 to 100 *RST: Spectrum mode: 100 PCT, with tracking generator...
  • Page 109: Format Subsystem

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 FORMat subsystem Manual operation: "Range Log Manual" on page 49 "Range Log 100 dB" on page 50 "Range Log 50 dB" on page 50 "Range Log 10 dB" on page 50 "Range Log 5 dB"...
  • Page 110: Input Subsystem

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 INPut subsystem Example: INIT:CONT OFF Switches the sequence to single sweep. INIT:CONT ON Switches the sequence to continuous sweep. Mode: Manual operation: "Continuous Sweep" on page 56 "Single Sweep" on page 56 INITiate<n>[:IMMediate]...
  • Page 111 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 INPut subsystem The attenuation can be set in 5 dB steps (with option R&S FSV-B25: 1 dB steps). If the defined reference level cannot be set for the set RF attenuation, the reference level is adjusted accordingly.
  • Page 112: Instrument Subsystem (Bluetooth, K8)

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 INSTrument Subsystem (BLUETOOTH, K8) INPut:IMPedance <Impedance> This command selects the nominal input impedance. 75 Ω should be selected if the 50 Ω input impedance is transformed to a higher impe- dance using a 75 Ω adapter of the RAZ type (= 25 Ω in series to the input impedance of the instrument).
  • Page 113 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 SENSe Subsystem (BLUETOOTH, K8) This command has the same effect as the [SENSe<source>:]SWEep:COUNt com- mand. In both cases, the number of measurements is defined whether the average cal- culation is active or not.
  • Page 114 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 SENSe Subsystem (BLUETOOTH, K8) Parameters: <Bandwidth> refer to data sheet *RST: (AUTO is set to ON) Example: BAND 1 MHz Sets the resolution bandwidth to 1 MHz [SENSe:]BANDwidth|BWIDth[:RESolution]:AUTO <State> This command couples and decouples the resolution bandwidth to the span.
  • Page 115 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 SENSe Subsystem (BLUETOOTH, K8) Parameters: <FilterType> NORMal Gaussian filters CFILter channel filters RRC filters 5 Pole filters *RST: NORMal Example: BAND:TYPE NORM Manual operation: "Filter Type (Output Power, TX Spec ACLR, Spurious Emis- sions, Rel TX Power)"...
  • Page 116 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 SENSe Subsystem (BLUETOOTH, K8) [SENSe:]SWEep:COUNt <NumberSweeps> This command defines the number of sweeps started with single sweep, which are used for calculating the average or maximum value. If the values 0 or 1 are set, one sweep is performed.
  • Page 117 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 SENSe Subsystem (BLUETOOTH, K8) [SENSe:]SWEep:EGATe:LENGth <TimeInterval> This command defines a gate length. Parameters: <TimeInterval> 125 ns to 30 s *RST: 400μs Example: SWE:EGAT:LENG 10ms Manual operation: "Gate Length (Spurious Emissions)" on page 47 [SENSe:]SWEep:EGATe:POLarity <Polarity>...
  • Page 118 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 SENSe Subsystem (BLUETOOTH, K8) [SENSe:]SWEep:MODE <Mode> This command selects the spurious emission and spectrum emission mask measure- ments. Parameters: <Mode> AUTO | ESPectrum | LIST AUTO Switches to "Spectrum" measurement mode or stays in the cur-...
  • Page 119: Sense:ademod Subsystem (Bluetooth, K8)

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 SENSe:ADEMod Subsystem (BLUETOOTH, K8) Parameters: <State> ON | OFF *RST: Example: SWE:TIME:AUTO ON Activates automatic sweep time. [SENSe:]SWEep:TYPE <Type> This command selects the sweep type. Parameters: <Type> Selects analog frequency sweeps.
  • Page 120: Sense:ddemod Subsystem (Bluetooth, K8)

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 SENSe:DDEMod Subsystem (BLUETOOTH, K8) Example: ADEM:ZOOM ON Switches on the zoom function Mode: Manual operation: "Zoom (Modulation Char, Init Carr Freq Tol, Carr Freq Drift)" on page 42 [SENSe:]ADEMod:ZOOM:STARt <Time> The command sets the start time for the display of individual measured values.
  • Page 121 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 SENSe:DDEMod Subsystem (BLUETOOTH, K8) This command is only available with active Modulation Characteristics, Initial Carrier Frequency Tolerance, and Carrier Frequency Drift measurement (see CONFigure:​ on page 96). With all other measurements it will lead to a BTOoth:​...
  • Page 122 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 SENSe:DDEMod Subsystem (BLUETOOTH, K8) Example: DDEM:SEAR:SYNC ON Switches the sync search on. Mode: BT, VSA Manual operation: "Find Sync On/Off" on page 38 [SENSe:]DDEMod:SEARch:SYNC:LAP <Bits> This command determines the 24 least significant bits (LAP) of the DUT 'Bluetooth device address'.
  • Page 123: System Subsystem

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 SYSTem subsystem Example: DDEM:SEAR:TIME 100US Sets the record length for sync word and burst search to 100 us. Mode: Manual operation: "Search Len Manual" on page 40 Table 4-4: Max. record length depending on points per symbol...
  • Page 124: Trace Subsystem

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 TRACe subsystem The best performance is obtained if the display output is switched off during remote control. Parameters: <State> ON | OFF *RST: SYST:DISP:UPD ON Example: 4.12 TRACe subsystem TRACe<n>[:DATA]? <ResultType>...
  • Page 125: Trigger Subsystem

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 TRIGger subsystem 4.13 TRIGger subsystem TRIGger<n>[:SEQuence]:IFPower:HOLDoff <Value> This command sets the holding time before the next IF power trigger event. Suffix: <n> irrelevant Parameters: <Value> *RST: 150 ns Example: TRIG:SOUR IFP Sets the IF power trigger source.
  • Page 126 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 TRIGger subsystem TRIGger<n>[:SEQuence]:LEVel:IFPower <TriggerLevel> This command defines the power level at the third intermediate frequency that must be exceeded to cause a trigger event. Note that any RF attenuation or preamplification is considered when the trigger level is analyzed.
  • Page 127: Programming Example

    ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 Programming Example Parameters: <Source> IMMediate Free Run EXTern External trigger IFPower Power trigger at the second intermediate frequency RFPower Power trigger at the first intermediate frequency VIDeo Video mode is only available in the time domain and only in Spectrum mode.
  • Page 128 ® Remote Commands for Bluetooth Measurements (K8) R&S FSV-K8 Programming Example Selects power class 1 CONF:BTO:PRAT 4 Selects 4 points per symbol CONF:BTO:PTYP DH1 Selects 1 slot packet DDEM:SEAR:SYNC ON Activates the FIND SYNC function DDEM:SEAR:SYNC:OFFS 0 Sets the sync offset = 0...
  • Page 129: List Of Commands

    ® List of Commands R&S FSV-K8 List of Commands [SENSe:]ADEMod:ZOOM:STARt........................120 [SENSe:]ADEMod:ZOOM[:STATe]........................119 [SENSe:]AVERage<n>:COUNt........................112 [SENSe:]AVERage<n>:TYPE........................113 [SENSe:]BANDwidth|BWIDth[:RESolution]....................113 [SENSe:]BANDwidth|BWIDth[:RESolution]:AUTO..................114 [SENSe:]BANDwidth|BWIDth[:RESolution]:RATio..................114 [SENSe:]BANDwidth|BWIDth[:RESolution]:TYPE..................114 [SENSe:]CORRection:EGAin:INPut[:MAGNitude]..................115 [SENSe:]DDEMod:FILTer:MEASurement......................120 [SENSe:]DDEMod:SEARch:PULSe:OFFSet....................121 [SENSe:]DDEMod:SEARch:PULSe[:STATe]....................121 [SENSe:]DDEMod:SEARch:SYNC:LAP......................122 [SENSe:]DDEMod:SEARch:SYNC:OFFSet....................122 [SENSe:]DDEMod:SEARch:TIME......................... 122 [SENSe:]DDEMod:SEARch:TIME:AUTO...................... 123 [SENSe:]FREQuency:CENTer........................115 [SENSe:]SWEep:COUNt..........................116 [SENSe:]SWEep:COUNt:CURRent?......................
  • Page 130 ® List of Commands R&S FSV-K8 CALCulate<n>:BTOoth:IBSemissions:TXReference?..................78 CALCulate<n>:BTOoth:ICFTolerance?......................79 CALCulate<n>:BTOoth:MCHar:DF<Delta>:AVERage?.................. 79 CALCulate<n>:BTOoth:MCHar:DF<Delta>:MAXimum?..................80 CALCulate<n>:BTOoth:MCHar:DF2:PERCent?....................81 CALCulate<n>:BTOoth:MCHar:RATio?......................82 CALCulate<n>:BTOoth:OPOWer:AVERage?....................83 CALCulate<n>:BTOoth:OPOWer[:PEAK]?......................83 CALCulate<n>:BTOoth:PLENgth?........................84 CALCulate<n>:BTOoth:PTYPe?........................85 CALCulate<n>:BTOoth:RTPower:[DPSK]?..................... 85 CALCulate<n>:BTOoth:RTPower:GFSK?....................... 86 CALCulate<n>:BTOoth:RTPower:RATio?....................... 87 CALCulate<n>:BTOoth:STATus?........................87 CALCulate<n>:DELTamarker<m>:Y?......................88 CALCulate<n>:MARKer<m>:PEXCursion....................... 89 CALCulate<n>:MARKer<m>:Y?........................90 CALCulate<n>:UNIT:POWer........................... 90 CONFigure:BTOoth:ACLR:ACPairs.........................91 CONFigure:BTOoth:BANDwidth|BWIDth:VIDeo....................93 CONFigure:BTOoth:BANDwidth|BWIDth:VIDeo:AUTO...................93 CONFigure:BTOoth:BANDwidth|BWIDth[:RESolution]..................92 CONFigure:BTOoth:BANDwidth|BWIDth[:RESolution]:AUTO.................92 CONFigure:BTOoth:CFSTability:BCOunt......................94 CONFigure:BTOoth:CHANnel.........................
  • Page 131 ® List of Commands R&S FSV-K8 DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RPOSition................107 DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RVALue................108 DISPlay[:WINDow<n>]:TRACe<t>[:STATe]....................105 FORMat[:DATA].............................109 INITiate<n>:CONTinuous..........................109 INITiate<n>[:IMMediate]..........................110 INPut:ATTenuation............................110 INPut:ATTenuation:AUTO..........................111 INPut:GAIN:STATe ............................111 INPut:IMPedance............................112 INSTrument:NSELect............................ 112 INSTrument[:SELect].............................112 SYSTem:DISPlay:UPDate..........................123 TRACe<n>[:DATA]?............................124 TRIGger<n>[:SEQuence]:HOLDoff[:TIME]....................125 TRIGger<n>[:SEQuence]:IFPower:HOLDoff....................125 TRIGger<n>[:SEQuence]:IFPower:HYSTeresis.................... 125 TRIGger<n>[:SEQuence]:LEVel:IFPower......................126 TRIGger<n>[:SEQuence]:SLOPe........................126 TRIGger<n>[:SEQuence]:SOURce....................... 126...
  • Page 132: Index

    ® Index R&S FSV-K8 Index Adjacent-Channel Power measurement (K8) ....24 filter amplitude menu K8 option ..............16 K8 option ..............49 Filter types antenna gain (K8) ..............37 5-Pole ................. 64 Attenuation EMI (6dB) ..............64 Automatic ..............52 Normal (3dB) .............. 64 Manual ..............
  • Page 133 ® Index R&S FSV-K8 sweep (K8) ..............56 Adjust Gate (K8) ............47 trigger (K8) ..............60 Adjust Gate (remote control, K8) ........ 96 mode Antenna Gain (K8) ............37 trigger ................60 Auto (remote control) ..........119 Modulation Accuracy measurement (K8) ......31 Average Mode (remote control) ........
  • Page 134 ® Index R&S FSV-K8 Power Avg Stop (remote control, K8) ......99 Video BW Manual (remote control, K8) ...... 93 Power Class (K8) ............37 Zoom (K8) ..........42, 43, 44, 58 Range ................. 49 Softkey Range Lin. Unit ............51 BB Power ..............
  • Page 135 ® Index R&S FSV-K8 trigger extern (K8) ..............19 external ............... 60 level ................62 slope ................63 Trigger Holdoff ................ 63 Hysteresis ..............63 Offset ................63 trigger concepts (K8) ............19 trigger menu K8 option ..............60 trigger mode ..............60 External ...............