FSV-K8
Video BW Manual (TX Spec
Video BW Auto (TX Spec ACLR, Spurious
Filter Type (Output Power, TX Spec ACLR, Spurious Emissions, Rel TX
Meas Filter (Modulation Char, Init Carr Freq Tol, Carr Freq
Sweeptime Manual (TX Spec ACLR)
Opens an edit dialog box to enter the sweep time. The valid value range is 10 μs (mini-
mum measurement time for one channel) to 16000 s. The default setting is 79 s.
Remote command:
CONFigure:​ B TOoth:​ S WEep:​ T IME​
Sweeptime Auto (TX Spec ACLR)
Activates the automatic calculation of the sweep time. The automatic sweep time cor-
responds to the settings defined in the RF Test Specification. By default, it is activated.
Remote command:
CONFigure:​ B TOoth:​ S WEep:​ T IME:​ A UTO​
Meas Time Manual
Opens an edit dialog box to enter the measurement time. The valid value range is 1 μs
to (400001 / points per symbol) μs.
This function is not available for Spurious Emissions measurements.
Remote command:
CONFigure:​ B TOoth:​ S WEep:​ T IME​
Meas Time Auto
Activates the automatic calculation of the measurement time. The automatic sweep
time corresponds to the settings defined in the RF Test Specification. By default, the
automatic sweep time calculation is activated.
This function is not available for Spurious Emissions measurements.
Remote command:
CONFigure:​ B TOoth:​ S WEep:​ T IME:​ A UTO​
Res BW Manual (Output Power, Rel TX Power)
Opens an edit dialog box to enter the resolution bandwidth. The values range from 1
MHz to 3 MHz. The default value is 3 MHz.
Remote command:
CONFigure:​ B TOoth:​ B ANDwidth|BWIDth[:​ R ESolution]​
Res BW Auto (Output Power, TX Spec ACLR, Rel TX Power, Spurious Emissions)
Sets the bandwidth according to the values defined in the RF Test Specification.
Remote command:
CONFigure:​ B TOoth:​ B ANDwidth|BWIDth[:​ R ESolution]:​ A UTO​
Video BW Manual (TX Spec ACLR)
The default value is 300 kHz, according to the values defined in the RF Test Specifica-
tion.
Operating Manual 1176.7610.02 ─ 02
Instrument Functions for Bluetooth Measurements (K8)
Softkeys of the Bandwidth Menu (option R&S FSV-K8)
ACLR)..............................................................................54
Emissions)................................................ 55
on page 103
on page 103
on page 103
on page 103
Power)........55
Drift)................................ 55
on page 92
on page 92
54

Advertisement

Table of Contents
loading

Table of Contents