R&S FSV-K8 Operating Manual page 115

Firmware option bluetooth measurements
Table of Contents

Advertisement

®
R&S
FSV-K8
Parameters:
<FilterType>
Example:
Manual operation:
[SENSe:]CORRection:EGAin:INPut[:MAGNitude]
This command makes an external gain known to the analyzer, which will take it into
account during the display of measurement results. With this function the gain of an
antenna or of an external preamplifier can be taken into account for the measurement
values.
The command is available if a tracking generator is installed and has been turned on.
Parameters:
Example:
Manual operation:
[SENSe:]FREQuency:CENTer <Frequency>
This command defines the center frequency (frequency domain) or measuring fre-
quency (time domain).
Parameters:
<Frequency>
Example:
Manual operation:
Operating Manual 1176.7610.02 ─ 02
Remote Commands for Bluetooth Measurements (K8)
NORMal
Gaussian filters
CFILter
channel filters
RRC
RRC filters
P5
5 Pole filters
*RST:
NORMal
BAND:TYPE NORM
See
"Filter Type (Output Power, TX Spec ACLR, Spurious Emis-
sions, Rel TX Power)"
Range:
-200 dB to 200 dB
*RST:
0 dB
CORR:EGA:INP 10DB
Takes 10 dB external gain into account.
See
"Antenna Gain"
on page 37
Range:
0 to fmax
*RST:
fmax/2
Default unit: Hz
f
is specified in the data sheet. min span is 10 Hz
max
FREQ:CENT 100 MHz
See
"Center"
on page 56
SENSe Subsystem (BLUETOOTH, K8)