[SENSe:]SWEep:EGATe:LENGth <TimeInterval>
This command defines a gate length.
Parameters:
<TimeInterval>
Example:
Manual operation:
[SENSe:]SWEep:EGATe:POLarity <Polarity>
This command determines the polarity of the external gate signal. The setting applies
both to the edge of an edge-triggered signal and the level of a level-triggered signal.
Parameters:
<Polarity>
Example:
[SENSe:]SWEep:EGATe:TYPE <Type>
This command sets the type of triggering by the external gate signal.
A delay between applying the gate signal and the start of recording measured values
can be defined, see
Parameters:
<Type>
Example:
Operating Manual 1176.7610.02 ─ 02
Remote Commands for Bluetooth Measurements (K8)
125 ns to 30 s
*RST:
400μs
SWE:EGAT:LENG 10ms
See
"Gate Length (Spurious Emissions)"
POSitive | NEGative
*RST:
POSitive
SWE:EGAT:POL POS
[SENSe:​ ] SWEep:​ E GATe:​ H OLDoff​
LEVel | EDGE
LEVel
The gate is level-triggered:
After detection of the gate signal, the gate remains open until the
gate signal disappears. The gate opening time cannot be
defined with the command
Note: Using gating with gate mode "level" and an IFP trigger
(see
TRIGger<n>[:​ S EQuence]:​ S OURce​
holdoff time for the IFP trigger is ignored for frequency sweep,
FFT sweep, zero span and IQ mode measurements.
EDGE
The gate is edge-triggered:
After detection of the set gate signal edge, the gate remains
open until the gate delay
has expired.
*RST:
EDGE
SWE:EGAT:TYPE EDGE