FSV-K8
Parameters:
<Position>
Example:
Manual operation:
DISPlay[:WINDow<n>]:TRACe<t>:Y[:SCALe]:RVALue <Value>
The command defines the power value assigned to the reference position in the grid.
When using a tracking generator, this command requires active normalization.
Suffix:
<n>
<t>
Parameters:
<Value>
Example:
DISPlay[:WINDow<n>]:TRACe<t>:Y:SPACing <ScalingType>
This command selects the scaling of the y-axis.
Suffix:
<n>
<t>
Parameters:
<ScalingType>
Example:
Operating Manual 1176.7610.02 ─ 02
Remote Commands for Bluetooth Measurements (K8)
0 PCT corresponds to the lower display border, 100% corre-
sponds to the upper display border.
Range:
0 to 100
*RST:
Spectrum mode: 100 PCT, with tracking generator
or time display: 50 PCT
Default unit: PCT
DISP:TRAC:Y:RPOS 50PCT
See
"Ref Level Position"
.
irrelevant
irrelevant
*RST:
0 dB, coupled to reference level
DISP:TRAC:Y:RVAL -20dBm
Defines a reference position of -20 dBm.
.
Selects the measurement window.
irrelevant
LOGarithmic
Logarithmic scaling.
LINear
Linear scaling in %.
LDB
Linear scaling in dB.
*RST:
LOGarithmic
DISP:TRAC:Y:SPAC LIN
Select a linear scale.
DISPlay Subsystem (BLUETOOTH, K8)
on page 52