Not available for Carr Freq Drift, Init Carr Freq Tol, and Modulation Char measure-
ments.
Remote command:
DISPlay[:​ W INDow<n>]:​ T RACe<t>:​ Y [:​ S CALe]:​ R POSition​
Grid Abs/Rel
Switches between absolute and relative scaling of the level axis (not available with
"Linear" range).
Not available for Carr Freq Drift, Init Carr Freq Tol, and Modulation Char measure-
ments.
"Abs"
"Rel"
Remote command:
DISPlay[:​ W INDow<n>]:​ T RACe<t>:​ Y [:​ S CALe]:​ M ODE​
Input 50 Ω/75 Ω
Uses 50 Ω or 75 Ω as reference impedance for the measured levels. Default setting is
50 Ω.
The setting 75 Ω should be selected if the 50 Ω input impedance is transformed to a
higher impedance using a 75 Ω adapter of the RAZ type (= 25 Ω in series to the input
impedance of the instrument). The correction value in this case is 1.76 dB = 10 log (75
Ω/50 Ω).
All levels specified in this Operating Manual refer to the default setting of the instru-
ment (50 Ω).
This function is not available for input from the R&S Digital I/Q Interface (option
R&S FSV-B17).
Remote command:
INPut:​ I MPedance​
3.6 Softkeys of the Bandwidth Menu (option R&S FSV-K8)
The following section describes all softkeys available in the "Bandwidth" menu in Blue-
tooth mode (BW key). It is possible that your instrument configuration does not provide
all softkeys. If a softkey is only available with a special option, model or (measurement)
mode, this information is delivered in the corresponding softkey description.
Sweeptime Manual (TX Spec
Sweeptime Auto (TX Spec
Meas Time
Meas Time
Res BW Manual (Output Power, Rel TX
Res BW Auto (Output Power, TX Spec ACLR, Rel TX Power, Spurious
Operating Manual 1176.7610.02 ─ 02
Instrument Functions for Bluetooth Measurements (K8)
Softkeys of the Bandwidth Menu (option R&S FSV-K8)
Absolute scaling: The labeling of the level lines refers to the absolute
value of the reference level. Absolute scaling is the default setting.
Relative scaling: The upper line of the grid is always at 0 dB. The
scaling is in dB whereas the reference level is always in the set unit
(for details on unit settings see the "Unit" softkey).
on page 112
ACLR)............................................................................54
ACLR)................................................................................ 54
Manual........................................................................................................54
Auto............................................................................................................ 54
on page 106
Power)...........................................................54
on page 107
Emissions)... 54
53

Advertisement

Table of Contents
loading

Table of Contents