FSV-K8
Result Summary
The results of the measurement are summarized in a table beneath the diagram. The
summary contains the following results:
Packet type
Packet length in symbols
Packet tested (Number of tested packets)
Packet passed (Number of successful tests, i.e. correctly modulated packets)
Bit error rate
3.2 Adapting the settings to the characteristics of the
DUT
1. Set the spectrum analyzer to its default state.
a) Press "PRESET".
The R&S FSV is set to its default state.
2. Select the Bluetooth operating mode.
a) Press "MODE" key.
b) In the "Measurement Modes" dialog box, select "Bluetooth".
The "Bluetooth" mode is activated and the main menu of the option is displayed.
3. Select the required measurement type to be performed.
a) Press "Standard" and select the required standard.
b) Press the softkey for the required measurement type.
The measurement configuration menu is displayed.
4. Select the transmit channel.
a) Press "Channel" softkey and enter the desired channel number.
5. Select the packet type and power class.
a) Press "Meas Setup".
b) Select the desired packet type.
c) Select the power class of the DUT.
d) Press "Close".
6. Configure the sync settings (LAP).
a) Press "Find Sync" softkey.
b) Enter the "LAP (lower address part)" of the Bluetooth device address of the
Operating Manual 1176.7610.02 ─ 02
Instrument Functions for Bluetooth Measurements (K8)
The "Meas Setup Settings" dialag box is displayed.
The "Find Sync" dialog box is displayed.
DUT. The sync word used for the sync search is calculated.

Adapting the settings to the characteristics of the DUT