Principally, setting the channel number has the same effect as changing the center fre-
quency. The major difference is that the center frequency is not limited to available fre-
quency band values, i.e. values outside the frequency band and between the discrete
channels can be selected (see also
Remote command:
CONFigure:​ B TOoth:​ C HANnel​
Meas Setup ← Carr Freq Drift
Opens a dialog box for common measurement settings, see
Find Sync ← Carr Freq Drift
Opens a dialog box to set the signal processing functions of the analyzer, see
Sync"
Zoom (Modulation Char, Init Carr Freq Tol, Carr Freq Drift) ← Carr Freq Drift
Activates or deactivates the zoom function. Opens an edit dialog box to enter the zoom
start position. The valid value range for the zoom start position is 0 to (measurement
time – 500 / sampling rate). The default setting for the zoom function is 0s (off).
With active zoom function, an area of only 501 samples is displayed.
Remote command:
[SENSe:​ ] ADEMod:​ Z OOM[:​ S TATe]​
[SENSe:​ ] ADEMod:​ Z OOM:​ S TARt​

Rel TX Power

Opens a submenu to configure the Rel TX Power measurement. For further details
refer to
Remote command:
CONF:BTO:MEAS RTP, see
CALCulate<n>:​ B TOoth:​ R TPower:​ [ DPSK]?​
CALCulate<n>:​ B TOoth:​ R TPower:​ G FSK?​
CALCulate<n>:​ B TOoth:​ R TPower:​ R ATio?​
Channel ← Rel TX Power
Opens an edit dialog box to enter the transmission channel number. From the number
of the channel the center frequency is calculated in accordance to the RF Test Specifi-
cation. The default setting is channel number 0.
Principally, setting the channel number has the same effect as changing the center fre-
quency. The major difference is that the center frequency is not limited to available fre-
quency band values, i.e. values outside the frequency band and between the discrete
channels can be selected (see also
Remote command:
CONFigure:​ B TOoth:​ C HANnel​
Meas Setup ← Rel TX Power
Opens a dialog box for common measurement settings, see
Operating Manual 1176.7610.02 ─ 02
Instrument Functions for Bluetooth Measurements (K8)
on page 37.
chapter 3.1.6, "Relative Transmit Power (EDR)
CONFigure:​ B TOoth:​ M EASurement​
Softkeys of the Bluetooth Menu
Center
softkey in the "Frequency" menu).
on page 94
on page 119
on page 120
Measurement", on page 28.
on page 85
on page 86
on page 87
Center
softkey in the "Frequency" menu).
on page 94

"Meas Setup"

on page 36.
"Find
on page 96
"Meas Setup"
on page 36.
44

Advertisement

Table of Contents
loading

Table of Contents