Configure:btooth:power:average:stop; Configure:btooth:prate - R&S FSV-K8 Operating Manual

Firmware option bluetooth measurements
Table of Contents

Advertisement

®
R&S
FSV-K8
Example:
Mode:
Manual operation:
CONFigure:BTOoth:POWer:AVERage:STOP <Position>
This command defines the end position for the calculation of the average power of a
burst.
Note:
Depending on the setting FIND SYNC ON or OFF (see
SYNC:​ S TATe​
length or the 3 dB points according to the RF Test Specification. As a result there are
different areas within the burst for calculating the average power (see
BTOoth:​ P OWer:​ A VERage:​ S TARt​
Parameters:
<Position>
Example:
Mode:
Manual operation:
CONFigure:BTOoth:PRATe <NoSamples>
This command selects the number of measurement samples (points) per symbol for
the measurement. This command is not avaiable for EDR measurements. For EDR
measurements, this parameter is set to 4 points/symbol and cannot be changed.
Note:
The RF Test Specification specifies an oversampling factor of at least 4.
Parameters:
<NoSamples>
Example:
Mode:
Manual operation:
Operating Manual 1176.7610.02 ─ 02
Remote Commands for Bluetooth Measurements (K8)
CONFigure:BTOoth Subsystem (BLUETOOTH, K8)
CONF:BTO:POW:AVER:STAR 10PCT
Sets the starting point for the calculation to 10% of the burst
length.
BT
See
"Power Avg Start (Output Power)"
on page 121) the burst is either defined by the p0 bit and the packet
on page 98).
0 to 100PCT
*RST:
80%
CONF:BTO:POW:AVER:STAR 90PCT
Sets the end point for the calculation to 90% of the burst length.
BT
See
"Power Avg Stop (Output Power)"
2 | 4 | 8 | 16 | 32
*RST:
4
CONF:BTO:PRAT 16
Selects 16 points/symbol.
BT
See
"Points / Symbol"
on page 40
[SENSe]:​ D DEMod:​ S EARch:​
on page 40
on page 37
CONFigure:​
99