The thread tension is monitored for every stitch during the documented
seam section. As soon as the thread tension falls outside the tolerance
range, the sewing process stops, and an error message is displayed.
If the seam record set is linked to a teach-in file, the data stored in the
teach-in file will overwrite the manually entered data.
Linking a thread tension teach-in file
A thread tension teach-in file is used to store all important data necessary
to set the tolerance for the electronically regulated thread tension (for ETT
only). It is possible to link such a teach-in file to every seam section.
A different teach-in file can be linked to each documented/free seam
section.
To link a teach-in file to a seam section:
1. Open the Seam record set display ( p. 99).
2. Press the Thread.Tens.Teach-In input field.
 The directory holding the teach-in files that are stored on the control
3. Select the desired teach-in file.
4. Confirm with OK.
You can view the stored values:
1. Open the Seam record set display ( p. 99).
2. Press the Edit button at Thread.Tens.Teach-In.
 The values stored in the teach-in file are displayed.
Information
If the seam section is linked to a teach-in file, the data stored in the
teach-in file will overwrite the manually entered data.
Adjusting the stroke
To set the desired stroke:
1. Open the Seam record set display ( p. 99).
2. Press the Stroke input field.
 An input window appears.
3. Enter the desired stroke.
4. Confirm with