6365
6366
6367
7270
9300
9310
9320
9330
9340
9350
9351
9352
252
Code
Type
Meaning
Information
Internal EEprom defective
Information
Internal EEprom defective
and external data not valid
(emergency operating
features only)
Information
Internal EEprom defective
and external data not valid
(emergency operating
features only)
Information
External CAN
Error
CAN cable not connected
Error
Tape feeder not connected
Error
Tape feeder in lowered
position
Information
Material thickness sensor not
connected
Error
Remaining thread monitor
not connected
Error
Upper machine head pcb is
not connected
Error
Lower machine head pcb is
not connected
Error
Left thread tension pcb is not
connected
Troubleshooting
Remedial action
• Replace control
• Replace control
• Replace control
• Check connection cables
• Perform software update
• Replace CAN slaves
• Check CAN cable
• Check connection cables
• Perform software update
• Replace the control of the
tape feeder
• Check connection cables
• Perform software update
• Replace material
thickness sensor
• Check connection cables
• Perform software update
• Replace remaining thread
monitor
• Check cable
• Perform software update
• Replace PCB
• Check cable
• Perform software update
• Replace PCB
• Check cable
• Perform software update
• Replace PCB
Operating Instructions 550-D800 - 01.0 - 05/2023