n Allowed Operations
This section of the Digital Keys Page will allow you to
set up the amount of times a Key can operate the sys -
tem (i.e. perform Arm/Disarm in Away, A and B Mode
operations) before it is locked out automatically.
Unlimited If this option is enabled, the Key will be able
to perform an unlimited number of operations. If this op -
tion is disabled, the required number of operations can
be programmed in the Operations field.
Maximum Operations This programming field will al -
low you to program the amount of times the Key can op -
erate the system (accepted values: 1 to 254).
The system will disable the Key automatically when the
'Maximum Operations' counter reaches its limit.
The 'Maximum Operations' counter can be cleared
and the Key re-enabled by entering a valid User Code
(refer to "Enable Key Control" under "User Code Type").
n Attributes
Patrol If this attribute is enabled, the Key will be able to Dis -
arm and Re-arm the Control panel during the programmed
Patrol Time. If a Partition is disarmed by a Key with the Pa -
trol attribute, the Partition will Re-arm automatically when
the programmed Patrol time of the Partition concerned ex -
pires (refer to "Patrol Time" in the "Partitions" section).
Arm only If this attribute is enabled, the Key will be able to
Arm the Control panel ONLY.
Disarm only If this attribute is enabled, the Key will be
able to Disarm the Control panel ONLY.
n Enable on Key Reader
The "Enable Key Reader" table will allow you enable the
code concerned on the Key Reader (32 Readers for
KYO320).
Figure 51 Wireless key page.
KYO320

KeyFobs

Systems with two VectorRX or VRX32-433 Receivers can
manage up to 32 keyFobs (with two VectorRX-8 up to 16
KeyFobs). The parameters description and programming
is shown in the following KeyFobs page (Fig.51).
This field shows the keyFob identification number
N.
which will be used in different parts of the application.
Description
the KeyFobs (e.g. the name of the Key User). This De -
scription will identify the KeyFob in all the operations it is
involved in.
1, 2, 3...32
tions. The KeyFob can be programmed to operate in 3
different modes on the system Partitions.
On/Off Button This row will allow you to Enable/Dis -
able the KeyFobs on the Partition (Check= KeyFob en -
abled on the relative Partition).
A mode (Amber) This row will allow you to enable the
status the Partition will assume when the KeyFob
makes an A Mode Arming request. The box will indi -
cate the selected mode (see the Mode section: A=
Away, S= Stay, I= Stay o Delay, D= Disarm, N= No
change.
B mode (Green) This row will allow you to enable the
status the Partition will assume when the KeyFob
makes an B Mode Arming request. The box will indi -
cate the selected mode (see the Mode section: A=
Away, S= Stay, I= Stay o Delay, D= Disarm, N= No
change.
Serial Number This editable field is for the ESN
6-digit
(Electronic Serial Number) of the KeyFob
(printed on back). The ESN may include hexadecimal
digits (A, B, C, D, E and F), in order to lower the risk of
duplicate ESNs.
PROGRAMMING
This editable field (16 characters) is for
These numbers correspond to the Parti -