n Replacing Wireless Devices
To replace a Wireless detector (assigned to a Wireless
Zone): select the required Wireless Zone, then enter
the ESN of the new Wireless detector in the Serial
Number field.
n Enrolling Wireless Devices
To enrol a Wireless detector: select an empty Wireless
Zone, then enter the Wireless detector ESN in the Se -
rial Number field.
n Unenrolling Wireless Devices
To unenrol a Wireless detector (assigned to a Wireless
Zone): select the required Wireless Zone then enter
000000 in the Serial Number field.

Outputs

Control panel Outputs no. 1, no. 2 and no. 3 are 3 A
double switching relays. The terminals for these Outputs
are:
Ø Output no. 1 = +N1, +A1, C1-NC1-NA1
Ø Output no. 2 = +N2, +A2, C2-NC2-NA2
Ø Output no. 3 = +N3, +A3, C3-NC3-NA3
The Control panel Outputs no. 4, no. 5 and no.6 are 1 A
Open-Collectors. The terminals for these Outputs are:
OC1, OC2 and OC3.
The Expander Outputs are 0.15 A Open-Collectors.
The terminals for these Outputs are OC1, OC2, OC3,
OC4, OC5 and OC6.
The Output Expander Buzzer 98 can be connected to
the terminal [OC6] via jumper 99:
Ø 1 ooo 3 = buzzer OFF (at default):
Ø 1 //o 3 = the buzzer will sound when the terminal
[OC6] opens;
Ø 1 o// 3 = the buzzer will sound when the terminal
[OC6] closes to Negative.
The Control Panel Outputs and Expander Outputs can be as -
sociated with Events that activate signalling devices (Sirens,
Flashers, etc.), or used to provide Operating/Trou -
ble status and device control signals. They can
also be used to turn ON/OFF electrical appliances
at the Keypad or via telephone (Heating, Garden
sprinklers, etc.). The Outputs page will allow
you to program the Control Panel and Ex -
pander Output parameters, as follows. The
table on the left side of the Outputs page
shows the Outputs. The number of available
Outputs depends on the system (refer to
"Configuration"). The following information
will be shown for each Output.
No. This field shows the Output ID number,
used in some parts of the application, instead
of the Output Description (refer to "Descrip -
tion").
KYO320
Position This field shows the Description of the Out -
put placement. This label can be edited on the Output
Expanders page.
Device This field shows the Address of the Output place -
ment (Control Panel Outputs are indicated by a hyphen).
Ter. This field shows the Output terminal tag:
Ø RL1 = +N1, +A1, C1-NC1-NA1
Ø RL2 = +N2, +A2, C2-NC2-NA2
Ø RL3 = +N3, +A3, C3-NC3-NA3
Description This editable field (16 characters) is for the
Output label (e.g. the detector placement or the name of
the Key User). The Parameters on the right side of the
Outputs page can be programmed as follows.
Type The Output can be programmed as either Mono -
stable (M) or Bistable (B).
Pol. The Output can be programmed as either
Normally Closed (NC) or Normally Open (NO).
n Type
Bistable This type of Output will activate when AT
LEAST ONE of its associated Events occurs, and will
stop when ALL of its associated Events end.
Monostable This type of Output will activate when AT LEAST
ONE of its associated Events occurs, and will stop when the pro -
grammed ON Time expires (see "ON Time" below).
n Polarity
This programming field will allow you to program the
Output standby polarity .
Normally Open The electrical state during standby is:
[+N] terminals open; Positive signal (13.8V) on the [+A]
terminals; [C] terminals closed to their respective [NO]
terminals; [NC] and [OC] terminals open.
Figure 30 Outputs page
PROGRAMMING
43