If the Wire less De vice Re ceiver op tion is Dis abled
(re fer to the Ac ces sories page), the left side of the
Wire less page will be empty.
No. This field shows the Wire less Zone which will be
used in some parts of the ap pli ca tion in stead of the
Wire less Zone.
Position This field shows the De scrip tion of the hard -
ware de vice the Wire less Zone is as signed to.
Description This editable field (16 char ac ters) is for the
Wire less Zone (e.g. the de tec tor place ment or the name
of the Key User). This De scrip tion will iden tify the Wire -
less De tec tor in all the op er a tions it is in volved in.
The right side of the page will al low you to pro gram the
pa ram e ters of the Wire less De vice (to be se lected on
the left), as fol lows.
The right side of the page shows the var i ous pa -
ram e ters for the Wire less Zones.
Serial Number This editable field is for the ESN (Elec -
tronic Se rial Num ber) of the Wire less de tec tor which is
as signed to the se lected Wire less Zone.
You can not pro gram the de vice pa ram e ters un til
you have en tered its ESN.
The ESN will al low the Con trol panel to iden tify the wire -
less de vice on the sys tem.
The ESN may com prise hex a dec i mal dig its (A, B, C, D,
E and F), in or der to lower the risk of du pli cate ESNs.
Some Wire less De vices have 5-digit and 6-digit
ESNs (printed on back), use ONLY 6-digit ESNs
with this Con trol panel.
Supervised If this op tion is En abled, the sys tem will be
able to sig nal the loss of the Wire less de tec tor. The Re -
ceiver will trig ger the Lost wire less zone
event as soon as the pro grammed Su per vi -
sory time ex pires (re fer to the Time su per vi -
sion zones un der "Ac ces sories" in the "Con -
fig u ra tion" sec tion). The place ment of Wire -
less de tec tor will not be in di cated, how ever,
the re spec tive in for ma tion will be re corded in
the log.
Type Re fer to "Type" un der "BPI Zones".
Voice Messages Re fer
sages" un der "Wired Zones".
Attributes Re fer to "At trib utes" un der "Hard -
wired Zones".
Cycles Re fer to "Cycles" un der "Hard wired
Zones".
9 M-IN/OUT Expander programmed as Output Expander or Input/Output Expander (see "M-IN/OUT
Programmable Input/Output Expander" in the "INSTALLATION" chapter).
KYO320
to
"Voice
mes -
Fig ure 30 Out puts page
PRO GRAM MING FROM THE PC
Partitions Re fer to "Par ti tions" un der "Hard wired Zones".
Full Arming Alarm Re fer to "Full Arming Alarm" un der
"Hard wired Zones".
Inactivity Re fer to "In ac tiv ity" un der "Hard wired Zones".
The In ac tiv ity Time of Wire less Zones must not be
less that 5 min utes.

Replacing Wireless Devices

To re place a Wire less de tec tor (as signed to a Wire less
Zone): se lect the re quired Wire less Zone, then en ter
the ESN of the new Wire less de tec tor in the Se rial
Num ber field.

Enrolling Wireless Devices

To en rol a Wire less de tec tor: se lect an empty Wire less
Zone, then en ter the Wire less de tec tor ESN in the Se -
rial Num ber field.

Unenrolling Wire less De vices

To unenrol a Wire less de tec tor (as signed to a Wire less
Zone): se lect the re quired Wire less Zone then en ter
000000 in the Se rial Num ber field.

Out puts

Con trol panel Out puts no. 1, no. 2 and no. 3 are 3 A dou -
ble switch ing re lays. The ter mi nals for these Out puts are:
Out put no. 1 = +N1, +A1, C1-NC1-NA1
Out put no. 2 = +N2, +A2, C2-NC2-NA2
Out put no. 3 = +N3, +A3, C3-NC3-NA3
The Con trol panel Out puts no. 4, no. 5 and no.6 are 1 A
Open-Col lec tors. The ter mi nals for these Out puts are:
OC1, OC2 and OC3.
The Ex pander Out puts
tors.The ter mi nals for these Out puts are T1, T2, T3, T4,
T5 and T6.
9
are 0.15 A Open-Col lec -
43