Enable Test Event; Installer Maintenance; Central Station Maintenance - Bentel Security KYO 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for KYO 320:
Table of Contents

Advertisement

Any changes made to the Cus tomer code on the
Teleservice page will af fect the Cus tomer code in
the Cus tomer Data win dow and vice versa.
Attempts This pro gram ming field will al low you to pro -
gram the max i mum num ber of call at tempts.
Valid en tries: 1 through 99
At de fault: 8

Enable Test Event

If this op tion is En abled, the Con trol panel will make
reg u lar Test Calls. The Test call con firms that the Con -
trol Panel is op er at ing prop erly. If the Con trol panel fails
to trans mit to the Cen tral sta tion for a long pe riod, it may
mean:
— the sys tem is op er at ing prop erly but no events have
oc curred or,
— there is a break down in trans mis sions.
If the Cen tral sta tion does not re ceive the Test Call at
the set time, it will be as sumed that there is a break -
down in trans mis sions.
To set up the Test call, use the Test event and/or
Teleservice, as fol lows.
Enable Test Call If this op tion is En abled, the Con trol
Panel will make the Test call at reg u lar in ter vals, in ac cor -
dance with the First Test and Re peat test event set tings.
If the En able Test Event is Dis abled, the Con trol
panel will not send the Test call.
Enable Test Event If this op tion is En abled, the Con -
trol panel will gen er ate the Test event in ac cor dance
with the First Test and Re peat test event pa ram e ters.
If this op tion is Dis abled (at de fault), the Test event will
be in hib ited.
First Test This pro gram ming field is for the date and
time of the first Test.
Sub se quent Test calls de pend on the Re peat test
event set ting.
Repeat test event This pro gram ming field is for the
in ter val be tween Test calls.
Initialize If you are down loading a new Test set ting
to the Con trol panel, you must se lect this but ton, oth -
er wise the new set ting will be ig nored.
If the en tered date and time are prior to the cur -
rent date and time on the com puter, the Ini tial -
ize but ton will be in hib ited. The Con trol Panel
must be con nected to the PC via se rial port or
tele phone.

Installer Maintenance

The In staller Main te nance sec tion will al low you to
pro gram the date and time of In staller Main te nance
Re quest sig nal.
KYO320
The In staller Main te nance Re quest will be sig nalled by the:
The Trou ble sig nal gen er ated by the In staller Main te -
nance Re quest and In staller Main te nance will ter mi -
nate when:
To set up the In staller Main te nance Re quest — En able
the Main te nance Re quest op tion and set the Date and
Time, as fol lows.
Date En ter the date of the In staller Main te nance Re -
quest sig nal.
Time En ter the time of In staller Main te nance Re quest
sig nal.
Description Edit the mes sage that will be shown on
Key pad (in View Mode) when an In staller Main te nance
Re quest is re ceived.
The Cen tral Sta tion Main te nance sec tion will al low
you to pro gram the date and time of the Mon i toring
Main te nance Re quest sig nal.
The Mon i toring Main te nance Re quest will be sig nalled
by the :
Fig ure 41 Event-Ac tions page
PRO GRAM MING FROM THE PC
In staller Main te nance event;
ON sta tus of the G in di ca tor on the key pad.
The Trou ble in di ca tor G sig nals var i ous Trou ble
events. The Trou ble de tails can be found on the
LCD Key pads (in View Mode). If the trou ble is re -
lated to an In staller Main te nance Re quest, the re -
spec tive mes sage will be shown (see the
De scrip tion field in the In staller Main te nance
sec tion).
the Teleservice page is down loaded;
the Date and Time of In staller Main te nance are pro -
grammed at the Key pad (re fer to "Teleservice" in the
KEYPAD PROGRAMMING MANUAL).

Central Station Maintenance

55