Ci cles
Nu mber
01
13. Using A or B, set the num ber of Cycles for the Out -
put con cer ned. The Cycles can be set for the Mo no sta -
ble Out puts only. Va lid en tries: 1 thro ugh 31 or
Ti me less. Press ENTER to go back to step 3.

Partition

From the Pro gram ming menu:
1. Using A or B, se lect the Par ti tions op tion.
PROGRAMMING
Partition
2. Press ENTER:
Partition n. 001
Partition
001
3.Press A or B to se lect the re qui red par ti tion, then
press ENTER.
De scri ption
Partition
001
4. Enter the par ti tion la bel (re fer to "Edi ting a text" un der
"Using the Key pad"), then press ENTER.
Entry time
mm.ss.
00.30
5. Enter the time (in mi nu tes and se conds) the system
must wait be fo re ge ne ra ting an Alarm on zone event
af ter vio la tion of an Entry de lay zone, then press E.
Exit time
mm.ss
00.15
6. Enter the Exit time (in mi nu tes and se conds). Vio la -
tion of an Armed Exit De lay zone will ge ne ra te the pro -
gram med Exit time. If vio la tion ends be fo re the Exit
time ex pi res the zone will not ge ne ra te the Alarm on
zone event.
Press ENTER to con ti nue.
Last exit time
mm.ss
00.15
7. Enter the Last exit time (in mi nu tes and se conds),
then press ENTER. Vio la tion of a Last exit zone will
ge ne ra te the Last exit time of the par ti tion the zone be -
longs to. This fe a tu re will al low the system to Arm as
soon as the Last exit time ex pi res. Va lid en tries for
Entry, Exit and Last exit ti mes: 0 mi nu tes 0 se conds
thro ugh 59 mi nu tes 59 se conds.
26
Auto arm timeout
Min.
010
8. Enter the time (in steps of 1 mi nu te) of the Auto-arm
ti me o ut si gnal.
Va lid en tries: 1 thro ugh 240 mi nu tes.
Press ENTER to con ti nue.
Options
Au toArm del.sigx
9. Using A or B, se lect the Au toArm del. sig. (re fer to
"Au to arm Si gnal"), Au to re set (re fer to "Au to re set on
Arming"), Di sarm with mem. (re fer to "Di sarm with
alarm me mory") or Con firm Alarm (re fer to "Di sarm
with alarm me mory") then, using ON or OFF, re spec ti -
vely, ena ble or di sa ble the op tion con cer ned, then
press ENTER.
If you se lect the Con firm Alarm op tion, you must en ter
the re spec ti ve Con firm time (in steps of 1 minute).
Va lid en tries: 30 to 60 minutes.
Con firm time
Sec.
0060
Press ENTER to con ti nue.
Ne gli gen ce time
None
10. Enter the Ne gli gen ce time (in steps of 1 mi nu te). If
the Ne gli gen ce time of a par ti tion ex pi res, the Con trol
pa nel will ge ne ra te the re spec ti ve Ne gli gen ce event.
The Ne gli gen ce time of a par ti tion will re fresh each
time the par ti tion is Armed.
Va lid en tries: 1 to 60000 mi nu tes, or en ter all ze ros to
set None.
Press ENTER to con ti nue.
Ext.r.toArmDelay
min.
05
11. Enter the Exten ded Re ady-to-Arm de lay, then
press ENTER.
Patrol Time
Min.
00010
12. Enter the re le vant Pa trol Time, then press ENTER.
Inhi bitArming---
None
13.Using A or B , se lect the Ti mer that will fil ter Arming
com mands, then press ENTER:
Inhi bitDi sar ---
None
14.Using A or B , se lect a Ti mer to fil ter the Di sarm com -
mands, then press ENTER.