Command from Telephone Keypad

During Dialler or Answer mode access the keys on the telephone keypad will operate as special function keys,
as follows.
n Exit Request
Press
The Panel will step back to Enter data status and emit a ready beep.
n Stop Alarm/On hook
Dialler mode access----press
Answer mode access----press
n Remote listen-in
Press
The User will be able to listen to sounds in the protected ambient.
Press
n Remote telephone access
Press
Press
+
This option can be used for Teleassistance. The elderly will find this option particularly useful, as they can use a
remote-control device (pendant) to send emergency messages, via the Panel, to the Central station. The Central
station will be able to identify the caller, and communicate with the person, via the Panel, when the emergency
message ends.
n Check input zone status (All)
Press
The Panel will play the active messages then step back to Enter data status and emit a ready beep.
+
A Standby status message and an Alarm status message can be assigned to each Input.
n Check input zone status
Press
The following situations may occur:
Ø Voice messages assigned to the input:
----the Panel will play the active message then step back to the Enter data status and emit a ready beep.
Ø No Voice messages assigned to the input:
In Standby status----the Panel will emit a beep (high tone), then step back to the Enter data status and emit a
ready beep.
In Alarm status----the Panel will emit 2 beeps (high tone), then step back to the Enter data status and emit a
ready beep.
n Disable Output
Press
The panel will disable the Output then step back to Enter data status and emit a ready beep.
+
This option applies to outputs that are Reserved for manual control. If the User code is not enabled for this option,
or a non-reserved output is requested the Panel will emit an error beep.
n Enable Output
Press
The panel will enable the Output then step back to Enter data status and emit a ready beep.
+
This option applies to outputs that are Reserved for manual control. If the User code is not enabled for this option,
or a non-reserved output is requested the Panel will emit an error beep.
n Arm Partition
Press
16
#
to exit the ongoing request.
*
*
1
to start the remote listen-in phase.
#
to exit this phase.
2
to start Remote telephone access (2Way communication with persons in the protected ambient).
#
to exit this phase.
300
to check the status of all the input zones with Voice messages.
3
then key in the identifier number of the required Input zone (refer to the MEMO).
4
then key in the identifier number of the Output to be disabled (refer to the MEMO).
5
then key in the identifier number of the Output to be disabled (refer to the MEMO).
6
then press the Partition identifier number key (refer to the MEMO).
Expandable multifunction control panel
to stop the alarm, end the Dialler call, and clear the Dialler call queue.
to stop the alarm and end the call to the Panel.
#
*
1
2
300
3??
4??
5??
6?
Academy40