Outputs - Bentel Security Kyo 320 Installation Manual

Expandable multifunction control panel
Hide thumbs Also See for Kyo 320:
Table of Contents

Advertisement

ALL the AND-Zo nes de tect vio la tion wit hin the set time.
Press ENTER to go back to step 3.
PROGRAMMING
Configuration

Outputs

From the PROGRAMMING menu:
PROGRAMMING
Con fi gu ra tion
1. Using A or B, se lect the Out puts op tion.
PROGRAMMING
Outputs
2. Press ENTER.
Output
n.
001
Output
001
3. Using A or B, se lect the Out put to be pro gram med
then press.
De scri ption
Output
001
4. Enter the Out put la bel (re fer to "Edi ting a text" un der
"Using the Key pad"), then press ENTER.
Output
001
Mo no stable
5.Using A or B, se lect the Out put Type (Mo no sta ble or
Bi sta ble), then press ENTER.
Output
001
Su perv.norm.clo
6.Using A or B, se lect the Out put Po la rity: Su -
perv.norm.clo (re fer to "Nor mally clo sed" and "Su per -
vi sed"), Nor mally open or Nor mally clo sed, then
press ENTER.
+
Only Out puts 1, 2 and 3 of KYO 320
gram med as
Su perv.norm.clo.
Follow
n.
---
None
7.Enter the ID num ber of the Out put which will be trac -
ked by the Out put con cer ned. Enter all ze ros if the Out -
4 Outputs relating to M-IN/OUT expanders programmed as Input and Output Expanders are NOT all usable, even
if they are shown on the display. For example, if Output Expander no. 1 is an M-IN/OUT Expander programmed
as an Expander with 4 Zones + 2 Outputs, Outputs 07, 08, 09 and 10 are NOT usable. In general, Outputs
[3+(x*6)], [3+(x*6)], [5+(x*6)] and [6+(x*6)] of M-IN/OUT Expanders programmed as Expanders with 4 Zones + 2
Outputs, and Outputs [5+(x*6)] and [6+(x*6)] of M-IN/OUT Expanders programmed as Expanders with 4 Outputs
+ 2 Zones, where "x" is the address of the Expander, are NOT usable.
KYO320
put is not to track anot her Out put.
The key pad will emit an au di ble er ror si gnal, if you:
Ø at tempt to pro gram a va lue ot her than "None" for an
Out put which is as so cia ted with an event;
Øat tempt to pro gram an Out put which has been pro -
gram med to track anot her Out put;
Øat tempt to pro gram the se lec ted Out put.
Press ENTER.
Options
Reser ved
8. Using ON or OFF, ena ble/di sa ble the Re ser ved at tri -
bu te ("û" me ans ena bled, and "-" di sa bled).
+
The Re ser ved and Fol low No. at tri bu tes ex clu de
each ot her au to ma ti cally. The Re ser ved Out puts
can not be as so cia ted with events.
Press ENTER:
Ass.timer n. ---
None
4
,
9. Using A or B, se lect the Ti mer which will con trol the
Out put, then press ENTER:
ON
Min.
10. Using A or B, se lect Mi nu tes or Se conds for the ON
time, then en ter the ON time for the Out put. Va lid en -
tries: 0.2 to 25.4 se conds in steps of 0.2 or 1 thro ugh
127 mi nu tes in steps of 1 mi nu te.
Press ENTER.
Off
Sec.
11. Enter the amo unt of time that must elap se (af ter
Out put re sto ral) be fo re the Out put can be re ac ti va ted.
The OFF time can be set for Mo no sta ble Out puts
ONLY. Va lid en tries: 1 thro ugh 255 se conds in steps of
1 se cond.
Press ENTER:
Oscil la tion
None
can be pro -
12. Using A or B, se lect the Half Cycle of the oscil la -
tion. The Out put will ac ti va te for the pro gram med time,
re sto re to standby for the same amo unt of time, and
then re ac ti va te.
Va lid en tries: 200 thro ugh 1400 msec (mil li se conds;
1000 msec = 1 se cond) in steps of 200 msec. Press E:
PROGRAM PANEL
-
time
003
time
006