Technology > Fixing System > Service work > When replacing parts
Specified value (range):
Center: 9.0 -/+ 1.0mm
Edge (145mm from the center of feeding paper): 9.0 -/+ 1.0mm
Edge
Center
Feeding direction
Edge
If measured value is out of the specified range, reinstall the replaced parts (film unit or
pressure roller) and then measure the nip width again.
MEMO:
Fixing nip width cannot be adjusted in the field
2
Technology > Fixing System > Service work > When replacing parts
145 mm
145 mm
F-2-124
2-92