REP 3.5 Fusing Assembly
PL 3.5 Fusing Assembly
Removal
WARNING:
Allow the Fusing Assembly to cool before servicing the product.
1.
Open the Rear Cover.
2.
Rotate the Fusing Assembly locking levers in the direction indicated by the arrows, then pull the
Fusing Assembly out of the printer. (Figure 1)
Replacement
1.
Replace in reverse order.
2.
Reset the Fusing Assembly Counter.
Figure 1
(Resetting
Counters)
Phaser 3610, WorkCentre 3615 Service Manual
Service Parts Disassembly
s3610-044
4-77