Step
Check the connection between the CONTROL
PANEL and the ESS PWB.
1
•
Is the UI HARNESS ASSEMBLY connected
securely?
•
Replace the UI HARNESS ASSEMBLY.
2
•
Does an error occur?
•
Replace the CONTROL PANEL.
Control Panel (3610)
3
(3615))
•
Does an error occur?
FIP 1. 11
016-404 Certificate DB Error
Cause:
Certificate DB access error.
Solution:
The Certificate DB is invalid. Initialize the Certificate DB and security setting and then restart the
printer.
FIP 1. 12
016-405 Certificate DB Error
Cause:
Invalid security setting error.
Solution:
Initialize the Certificate DB and security setting and then restart the printer. Contact the admin-
istrator for security resetting.
Check and Action
(REP 1.1
/
REP 1.12 Control Panel
Yes
Go to Step 2.
Go to Step 3.
Replace
(REP 5.1 ESS
PWB)
Phaser 3610, WorkCentre 3615 Service Manual 2-131
Troubleshooting
No
Securely
connect the UI
HARNESS ASSEM-
BLY
Troubleshooting
complete.
Troubleshooting
complete.