FIP 1. 257
050-130 IOT Remain Zone Fusing Jam
051-130 is displayed in the UI.
Either of the following error codes is registered in the Error Log.
•
077-104 Regi Off Jam
•
077-106 Exit On Jam
•
077-108 Exit Off Early Jam
077-109 Exit Off Jam
•
Cause:
When Dynamic Jam (cause) was detected:
•
077-104 Regi Off Jam
•
077-106 Exit On Jam
•
077-108 Exit Off Early Jam
•
077-109 Exit Off Jam
When Static Jam (collateral) was detected:
•
Exit Sensor On
Solution:
Paper jam has occurred. Remove the jammed paper.
If there is no jammed paper, or the error still occurs after having removed the jammed paper,
turn the power Off and On to check that the error recurs, then proceed to the appropriate FIP.
•
For 077-104 Regi Off Jam, go to
•
For 077-106 Exit On Jam, 077-108 Exit Off Early Jam, and 077-109 Exit Off Jam,
go to
FIP 1. 284
FIP 1. 283
Phaser 3610, WorkCentre 3615 Service Manual 2-249
Troubleshooting