Troubleshooting
FIP 2.03
Registration Sensor
Cause:
Parts to be considered:
•
REGI-ACTUATOR
•
REGI-SENSOR
•
HVPS HARNESS ASSEMBLY
•
MCU PWB
Solution:
Step
Are there any foreign substances in the REGI-
1
SENSOR HVPS DETECTOR?
Is the REGI-ACTUATOR damaged?
2
Check the connection between the HVPS and the
MCU PWB.
3
•
Is the HVPS HARNESS ASSEMBLY (P/J261 -
P/J26) connected securely?
•
Replace the HVPS HARNESS ASSEMBLY.
4
•
Does an error occur?
•
Replace
HVPS
5
•
Does an error occur?
2-316
Phaser 3610, WorkCentre 3615 Service Manual
(PL 2.2 Transport
(PL 5.3 Electrical (MCU PWB /
(PL 5.4 Electrical
(PL 5.3 Electrical (MCU PWB /
Check and Action
(REP 5.7 HVPS
(3610))
(3615))
Assembly)
HVPS))
Connections)
HVPS))
Remove the for-
eign substances
Replace the
REGI-ACTUA-
Go to Step 4.
Go to Step 5.
(REP 5.8
Replace
(REP 5.6 MCU
Yes
No
Go to Step 2.
Go to Step 3.
TOR
Securely connect
the HVPS HAR-
NESS ASSEMBLY
Troubleshooting
complete.
Troubleshooting
complete.
PWB)