Xerox Phaser 3610 Service Manual page 352

Hide thumbs Also See for Phaser 3610:
Table of Contents

Advertisement

Troubleshooting
FIP 1. 331
117-361 IIT Parameter Verify NG
Cause:
IIT registration adjustment value verification NG.
(Checked only at production process)
Solution:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
FIP 1. 332
117-362 EEPROM Sum Check Error
Cause:
EEPROM sum check value error.
Solution:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
FIP 1. 333
117-363 NVM Sum Check Error
Cause:
NVM sum check value error.
Solution:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.