FIP 1. 192
033-755 Phase2 Error
Cause:
Phase2 (Line Probing) error.
Solution:
The machine will recover after the OK or Close button is pressed or message is displayed for
specified time.
If the error persists:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
3. If the problem cannot be solved, replace the following parts in sequence.
•
(REP 5.4 Fax
•
(REP 5.1 ESS
FIP 1. 193
033-756 Phase3 Error
Cause:
Phase3(Primary Channel Equalizer Training) error.
Solution:
The machine will recover after the OK or Close button is pressed or message is displayed for
specified time.
If the error persists:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
3. If the problem cannot be solved, replace the following parts in sequence.
•
(REP 5.4 Fax
•
(REP 5.1 ESS
PWB)
PWB)
PWB)
PWB)
Phaser 3610, WorkCentre 3615 Service Manual 2-215
Troubleshooting