FIP 1. 63
016-786 Data Send/Receive Timeout Error
Cause:
Timeout error occurs in scan data send/receive.
Solution:
The machine will recover after the OK button is pressed or message is displayed for specified
time.
If the error persists:
1. Check if the network cable is disconnected or connected properly. When there is no problem
with network cable, contact Server Administrator.
2. Perform the following in sequence.
•
" Network System Fault Check"
•
" Network-related Details Check Flow"
3. Take corrective actions at the host side.
FIP 1. 64
016-790 F2N Module Starting-up
Cause:
F2N module task is starting up, or IP address is not determined.
Solution:
The machine will recover after the OK button is pressed or message is displayed for specified
time.
If the error persists:
1. Check if the network cable is disconnected or connected properly. When there is no problem
with network cable, contact Server Administrator.
2. Take corrective actions at the host side.
Phaser 3610, WorkCentre 3615 Service Manual 2-151
Troubleshooting