Troubleshooting Procedure (Continued)
Step
Actions and Questions
Is the Drum Cartridge installed properly, with no
foreign substances at the contact point between
9
the ATC Sensor in the Drum Cartridge and the
Xerographic Connector Assembly?
Is the connection terminal of the ATC Sensor part
10
in the Drum Cartridge damaged?
Is the connection terminal of the Xerographic
11
Connector Assembly damaged?
12
Is the image printed correctly?
Reseat the HVPS.
13
Is the image printed correctly?
Replace the Drum Cartridge.
14
Is the image printed correctly?
Yes
Go to Step 10.
Replace the Drum Car-
tridge, then go to
step 11.
Replace
(REP 3.3
Xerographic Connector
Assembly) then go to
step 12.
Troubleshooting
complete.
Troubleshooting
complete.
Troubleshooting
complete.
Phaser 3610, WorkCentre 3615 Service Manual
Image Quality
No
Reinstall the Drum Car-
tridge, then go to
step 10.
Go to Step 11.
Go to Step 12.
Go to step 13.
Go to step 14.
Replace
(REP 5.7 HVPS
(3610)
/
REP 5.8 HVPS
(3615)).