FIP 1. 291
091-953 Drum Tape Staying
Cause:
The remaining Tape of the Drum Cartridge was detected.
Solution:
Remove the Drum Cartridge Tape.
FIP 1. 292
092-315 ATC Fail
Cause:
The ATC Sensor error was detected.
Solution:
Turn the power Off and On to check that the error recurs, then proceed to the FIP.
Step
Is the DRUM CARTRIDGE installed properly,
with no foreign substances at the contact point
between the ATC Sensor in the DRUM CAR-
1
TRIDGE and the XEROGRAPHIC CONNECTOR
ASSEMBLY?
Is the connection terminal of the ATC SENSOR
2
part in the DRUM CARTRIDGE damaged?
Is the connection terminal of the XERO-
3
GRAPHIC CONNECTOR ASSEMBLY damaged?
Check the connection between the
XEROGRAPHIC CONNECTOR ASSEMBLY
and the MCU PWB.
4
Is the XEROGRAPHIC CRUM HARNESS
ASSEMBLY(P/J254 - P/J25) connected
securely?
Replace the DRUM CARTRIDGE.
5
Does an error occur?
Check and Action
Yes
Go to Step 2.
Replace the
DRUM CAR-
TRIDGE
Replace
(REP 3.3 Xero-
graphic Connec-
tor
Assembly)
Go to Step 5.
Go to Step 6.
Phaser 3610, WorkCentre 3615 Service Manual 2-277
Troubleshooting
No
Reinstall the
DRUM CAR-
TRIDGE
Go to Step 3.
Go to Step 4.
Securely connect
the XERO-
GRAPHIC CRUM
HARNESS ASSEM-
BLY
Troubleshooting
complete.