Xerox Phaser 3610 Service Manual page 306

Hide thumbs Also See for Phaser 3610:
Table of Contents

Advertisement

Troubleshooting
FIP 1. 256
042-700 IOT Over Heat Stop
092-661 IOT Environment Sensor Error
Cause:
042-700: The Temp. Sensor sensed high temperature.
092-661: The Temp. Sensor or the Humidity Sensor error was detected.
Solution:
042-700:
Printing has been suspended because inside of the printer is extraordinarily hot.
Start the operation after the Printer has cooled down.
Turn the power Off and On to check that the error recurs. Then proceed to the FIP.
092-661:
Turn the power Off and On to check that the error recurs. Then proceed to the FIP.
Step
Is there a heat source near the device?
1
Are there any foreign substances in the Temp.
2
Sensor /Humidity Sensor HVPS Detector?
Check the connection between the HVPS
and the MCU PWB.
3
Is the HVPS HARNESS ASSEMBLY connected
securely?
Replace the HVPS HARNESS ASSEMBLY.
4
Does an error occur?
Replace
HVPS
5
Does an error occur?
2-248
Phaser 3610, WorkCentre 3615 Service Manual
Check and Action
(REP 5.7 HVPS
(3610))
(3615)).
Remove the heat
source
Remove the for-
eign substances
Go to Step 4.
Go to Step 5.
(REP 5.8
Replace
(REP 5.6 MCU
PWB)
Yes
No
Go to Step 2.
Go to Step 3.
Securely con-
nect the HVPS
HARNESS
ASSEMBLY
Troubleshooting
complete.
Troubleshooting
complete.

Hide quick links: