Troubleshooting
FIP 1. 256
042-700 IOT Over Heat Stop
092-661 IOT Environment Sensor Error
Cause:
042-700: The Temp. Sensor sensed high temperature.
092-661: The Temp. Sensor or the Humidity Sensor error was detected.
Solution:
042-700:
•
Printing has been suspended because inside of the printer is extraordinarily hot.
•
Start the operation after the Printer has cooled down.
•
Turn the power Off and On to check that the error recurs. Then proceed to the FIP.
092-661:
Turn the power Off and On to check that the error recurs. Then proceed to the FIP.
Step
Is there a heat source near the device?
1
Are there any foreign substances in the Temp.
2
Sensor /Humidity Sensor HVPS Detector?
•
Check the connection between the HVPS
and the MCU PWB.
3
•
Is the HVPS HARNESS ASSEMBLY connected
securely?
•
Replace the HVPS HARNESS ASSEMBLY.
4
•
Does an error occur?
•
Replace
HVPS
5
•
Does an error occur?
2-248
Phaser 3610, WorkCentre 3615 Service Manual
Check and Action
(REP 5.7 HVPS
(3610))
(3615)).
Remove the heat
source
Remove the for-
eign substances
Go to Step 4.
Go to Step 5.
(REP 5.8
Replace
(REP 5.6 MCU
PWB)
Yes
No
Go to Step 2.
Go to Step 3.
Securely con-
nect the HVPS
HARNESS
ASSEMBLY
Troubleshooting
complete.
Troubleshooting
complete.