FIP 1. 328
117-340 Controller Error
Cause:
HOOK task error.
Solution:
1. Turn the power Off and On to check that the error recurs, then update to the latest F/W.
2. If the problem cannot be solved, replace the following parts in sequence.
•
(REP 5.4 Fax
•
(REP 5.1 ESS
FIP 1. 329
117-344 FAX Error
Cause:
FLASHFILE task error.
Solution:
1. Turn the power Off and On to check that the error recurs, then update to the latest F/W.
2. If the problem cannot be solved, replace the following parts in sequence.
•
(REP 5.4 Fax
•
(REP 5.1 ESS
FIP 1. 330
117-350 Controller Error
Cause:
Task initialization (start) error.
Solution:
1. Turn the power Off and On to check that the error recurs.
2. Update to the latest F/W.
3. If the problem cannot be solved, replace
PWB)
PWB)
PWB)
PWB)
(REP 5.1 ESS
PWB).
Phaser 3610, WorkCentre 3615 Service Manual 2-293
Troubleshooting