Module 53 - Segmentation Via Fixed Positions - Leuze electronic BCL 248i Operating Instructions Manual

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
8.10.2 Module 53 – Segmentation via fixed positions
PROFINET-IO module identifier
Module ID: 1053
Submodule ID: 1
Description
The module activates the segmentation via fixed positions. The parameters specify the identifiers to be
searched for, the output mode, and the positions.
Parameter
Tab. 8.30:
Parameters for module 53
Parameter
Identifier list
Identifier 1
Identifier 2
Identifier 3
Identifier 4
Identifier 5
Identifier output
Output with
identifier
Output delimiter This delimiter, if not equal to 0, is
Fixed positions
Start position of
the 1st identifier
Leuze electronic GmbH + Co. KG
Description
The identifier string is used for the
identifier list and the filtering ac-
cording to the segmentation.
See identifier 1
See identifier 1
See identifier 1
See identifier 1
If this switch is not set, the output
of the identifiers is suppressed.
Only the data values that belong
to the identifiers are displayed in
this case.
inserted between the identifier
and the associated data value in
the output.
Specifies the position of the first
character of the first identifier in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
Addr. Data type
0
STRING
5 characters
null termi-
nated
5
STRING
5 characters
null termi-
nated
10
STRING
5 characters
null termi-
nated
15
STRING
5 characters
null termi-
nated
20
STRING
5 characters
null termi-
nated
25.0
Bit
26
UNSIGNED8 0 ... 127
27
UNSIGNED8 0 ... 127
BCL 248i
Value range
Default
1 ... 5 bytes of
'*'
ASCII characters
1 ... 5 bytes of
\0
ASCII characters
1 ... 5 bytes of
\0
ASCII characters
1 ... 5 bytes of
\0
ASCII characters
1 ... 5 bytes of
\0
ASCII characters
0: Output of the
1
identifiers is sup-
pressed.
1: Identifiers are
output.
0
0
79