Starting up the device - Configuration
The autoReflAct function uses the scanning beam to simulate a photoelectric sensor and thus permits an
activation without additional sensors. This is achieved by directing the scanner with reduced scanning
beam towards a reflector mounted behind the conveyor path. As long as the scanner is targeted at the re-
flector, the reading gate remains closed. If, however, the reflector is blocked by an object such as a con-
tainer with a bar code label, the scanner activates the read procedure, and the label on the container is
read. When the path from the scanner to the reflector has cleared, the read procedure has completed and
the scanning beam is reduced and again directed onto the reflector. The reading gate is closed.
Parameter
Tab. 8.48:
Parameters for module 91
Parameter
Mode
Debouncing
Parameter length
2 bytes
Input data
None
Output data
None
8.15.3 Module 92 – AutoControl
PROFINET-IO module identifier
Module ID: 1092
Submodule ID: 1
Description
The module defines the mode of operation of the function AutoControl. The function monitors the quality of
the decoded bar codes and compares these with a limit value. If the limit is reached, a status is set.
Parameter
Tab. 8.49:
Parameters for module 92
Parameter
AutoControl en-
able
Leuze electronic GmbH + Co. KG
Description
This parameter activates the
function of the diffuse laser sen-
sor. If "Autom. reading gate con-
trol" is set as the parameter
value, the BCL activates the
reading gate automatically if the
reflector is obscured.
The parameter defines the de-
bounce time in scans for the re-
flector detection. With a motor
speed of 1000, 1 scan corre-
sponds to a debounce time of
1 ms.
Description
This parameter can be used to acti-
vate or deactivate the AutoControl
function
Addr. Data type
0
UNSIGNED8 0: Normal
1
UNSIGNED8 1 ... 16
Addr. Data type
0
UNSIGNED8 0: Deacti-
BCL 248i
Value range
Default
0
AutoreflAct switched
off.
1: Auto
AutoreflAct activated.
Automatic reading
gate control.
2: Manual
AutoreflAct activated.
No reading gate con-
trol, signaling only.
5
Value range
Default
0
vated
1: Activated