Leuze electronic BCL 248i Operating Instructions Manual page 122

Bar code reader
Table of Contents

Advertisement

Online commands
Command
Acknowledgment
positive
Acknowledgment
negative
Writing parameter set
Command
Description
Leuze electronic GmbH + Co. KG
'PD'
PT<BCC><PS-Type><Status><Address><Parameter Value Address><Parameter
Value Address+1>... [;<Address><Parameter Value Address>]
<BCC>
Check-digit function during transmission, unit [dimensionless]
'0'
No check digits
'3'
BCC mode 3
<PS type>
Memory from which the values are to be read, unit [dimensionless]
'0'
Values stored in flash memory
'3'
Operating values stored in RAM
<Status>
Mode of parameter processing, unit [dimensionless]
'0'
No further parameters
'1'
Additional parameters follow
<Ad-
Relative address of the data within the data set, four-digit, unit [dimen-
dress>'aaaa'
sionless]
<P.value>
Parameter value of the parameter stored at this address. The 'bb' pa-
rameter set data is converted for transmission from HEX format to a 2-
byte-ASCII format.
'PS=<aa>'
Parameter reply:
<aa>
Status acknowledgment, unit [dimensionless]
'0'
No difference
'1'
Syntax error
'2'
Impermissible command length
'6'
Impermissible combination, parameter set 1 and parameter set
2
'8'
Invalid parameter set
'PT'
The parameters of the bar code reader are grouped together in a parameter set and
permanently stored in memory. There is one parameter set in permanent memory and
one operating parameter set in volatile memory; in addition, there is a default parame-
ter set (factory parameter set) for initialization. This command can be used to edit the
first two parameter sets (in permanent and volatile memory). A check sum can be
used for reliable parameter transfer.
BCL 248i
122