Module 35 - Bar Code Length; Module 36 - Scans With Information - Leuze electronic BCL 248i Operating Instructions Manual

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
Output data
None
8.8.8
Module 35 – Bar code length
PROFINET-IO module identifier
Module ID: 1035
Submodule ID: 1
Description
The module defines input data for the communication of the length of the currently output bar code.
Parameter
None
Input data
Tab. 8.21:
Input data for module 35
Input data
Bar code length Length/duration of the currently output
Input data length
2 byte consistent
Output data
None
8.8.9
Module 36 – Scans with information
PROFINET-IO module identifier
Module ID: 1036
Submodule ID: 1
Description
The module defines input data for the communication of the calculated number of scans which provided in-
formation contributing to the result of the bar code.
Parameter
None
Input data
Tab. 8.22:
Input data for module 36
Input data
Scans with information per bar
code
Input data length
2 byte consistent
Output data
None
Leuze electronic GmbH + Co. KG
Description
bar code, beginning with the code po-
sition specified in module 35 in 1/10
degrees.
Description
See above
Addr. Data type
0 ... 1 UN-
SIGNED16
Addr. Data type
0 ... 1 UN-
SIGNED16
BCL 248i
Value
Initial value
range
1 ... 900
1 [1/10 de-
[1/10 de-
grees]
grees]
Value range
Initial
value
0 ,,, 65535
0
72