8.15.1 Module 90 – Status and control
PROFINET-IO module identifier
Module ID: 1090
Submodule ID: 1
Description
This module supplies various BCL 248i status information to the PROFINET-IO master. Various functions
of the BCL 248i can be controlled via the master's output data.
Parameter
None
Input data
Tab. 8.47:
Input data for module 90
Input data
Reserved
AutoReflAct
state
AutoControl re-
sult
Reserved
RefCode com-
parison state 1
RefCode com-
parison state 2
Input data length:
1 byte
Output data
None
8.15.2 Module 91 – AutoReflAct (automatic reflector activation)
PROFINET-IO module identifier
Module ID: 1091
Submodule ID: 1
Description
The module defines the mode of operation of the diffuse laser sensor for controlling the reading gate.
Leuze electronic GmbH + Co. KG
Description
Free
Signal state of the AutoReflAct
module
Indicates whether the result of the
AutoControl function was a suc-
cessful or unsuccessful reading.
Free
The signal indicates whether the
decoded bar code corresponds to
the reference code with regard to
the comparison criteria as defined
in the comparison function 1. If it
matches, the value 1 is output.
The signal indicates whether the
decoded bar code corresponds to
the reference code with regard to
the comparison criteria as defined
in the comparison function 2. If it
matches, the value 1 is output.
Addr. Data
type
0.0
Bit
0.1
Bit
0.2
Bit
0.3
Bit
0.4 ...
Bit
 0.5
0.6 ...
Bit
 0.7
BCL 248i
Value range
Initial
value
0: Reflector is recog-
1
nized
1: Reflector is hidden
0: Quality good
0
1: Quality bad
0: Not equal
2
1: Equal
2: Unknown
0: Not equal
2
1: Equal
2: Unknown