Leuze electronic BCL 248i Operating Instructions Manual page 120

Bar code reader
Table of Contents

Advertisement

Online commands
Request parameter data set of the bar code reader
Command
Description
Parameter
Acknowledgment
positive
Leuze electronic GmbH + Co. KG
'PR'
The parameters of the bar code reader are grouped together in a parameter set and
permanently stored in memory. There is one parameter set in permanent memory and
one operating parameter set in volatile memory; in addition, there is a default parame-
ter set (factory parameter set) for initialization. This command can be used to edit the
first two parameter sets (in permanent and volatile memory). A check sum can be
used for reliable parameter transfer.
'PR<BCC type><PS type><Address><Data length>[<BCC>]'
<BCC type>
Check-digit function during transmission, unit [dimensionless]
'0'
Not used
'3'
BCC mode 3
<PS type>
Memory from which the values are to be read, unit [dimensionless]
'0'
Parameter values stored in the flash memory
'1'
Reserved
'2'
Default values
'3'
Operating values in RAM
<Ad-
Relative address of the data within the data set, four-digit, unit [dimen-
dress>'aaaa'
sionless]
<Data
Length of the parameter data to be transferred, four-digit, unit [length in
length>'bbbb'
bytes]
<BCC>
Check sum calculated as specified under BCC type
PT<BCC-Type><PS-Type><Status><Start><Parameter Value Address><Parameter
Value Address+1>...[;<Address><Parameter Value Address>][<BCC>]
<BCC type>
Check-digit function during transmission, unit [dimensionless]
'0'
Not used
'3'
BCC mode 3
<PS type>
Memory from which the values are to be read, unit [dimensionless]
'0'
Parameter values stored in flash memory
'2'
Default values
'3'
Operating values in RAM
<Status>
Mode of parameter processing, unit [dimensionless]
'0'
No further parameters
'1'
Additional parameters follow
<Start>'aaaa' Relative address of the data within the data set, four-digit, unit [dimen-
sionless]
<P.value A.>
Parameter value of the parameter stored at this address; the parameter
set data 'bb' is converted from HEX format to a 2-byte ASCII-format for
transfer.
<BCC>
Check sum calculated as specified under BCC type,
BCL 248i
120

Advertisement

Table of Contents
loading

Table of Contents