Starting up the device - Configuration
Parameter
Tab. 8.4:
Parameters for module 5
Parameter
Maximum width de-
viation
Code 39 max. ele-
ment ratio
Code 39 character
gap
Codabar max. ele-
ment ratio
Codabar character
gap
Codabar Monarch
Mode
Codabar start/stop
character
UPC-E extension
Code 128: activate
EAN header
Code 39 conversion Defines the conversion method
Parameter length
6 bytes
Input data
None
Output data
None
Leuze electronic GmbH + Co. KG
Description
Max. permitted width deviation
of a character in percent of the
directly adjacent character
Permissible ratio between maxi-
mum and minimum element of
Code 39.
Permissible ratio for the gap be-
tween two characters for
Code 39.
Permissible ratio between maxi-
mum and minimum element of
the Codabar code.
Permissible ratio for the gap be-
tween two characters for the
Codabar code.
The decoding of a Monarch bar
code as Codabar bar code can
be switched on or off.
Switches the transmission of a
start and stop character for the
Codabar code on and off.
Switches the extension of a
UPC-E code to a UPC-A result
on and off.
Switches the output of the EAN
header on and off.
used for Code 39.
BCL 248i
Addr
Data type
Value range
.
0
UN-
0 ... 100%
SIGNED8
1
UN-
0 ... 255
SIGNED8
2
UN-
0 ... 255
SIGNED8
3
UN-
0 ... 255
SIGNED8
4
UN-
0 ... 255
SIGNED8
5.0
Bit
0: Off
1: On
5.1
Bit
0: Off
1: On
5.4
Bit
0: Off
1: On
5.5
Bit
0: Off
1: On
5.6
BitArea
0: Standard (usual
... 5.
conversion
7
method)
1: Standard ASCII
(combination of
standard method
and ASCII
method)
2: ASCII (This
conversion
method uses the
entire ASCII char-
acter set)
Default
15 %
8
3
8
3
0
0
0
1
0