Control Modules; Module 10 - Activations - Leuze electronic BCL 248i Operating Instructions Manual

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
8.7

Control modules

8.7.1
Module 10 – Activations
PROFINET-IO module identifier
Module ID: 1010
Submodule ID: 1
Description
The module defines the control signals for the reading operation of the bar code reader. It is possible to se-
lect between standard reading operation and handshake operation.
In handshake operation, the control must acknowledge the data reception via the ACK bit before the new
data is written into the input area.
After acknowledging the last decoding result, the input data is reset (filled with zeros).
Parameter
Tab. 8.6:
Parameters for module 10
Parameter
Mode
Parameter length
1 byte
Input data
None
Output data
Tab. 8.7:
Output data for module 10
Output data
Reading gate Signal for activating the reading gate
Data ac-
knowledg-
ment
Data reset
Leuze electronic GmbH + Co. KG
Description
The parameter defines the mode in which
the activation module is operated.
Description
Free
Free
Free
This control bit signals that the transmitted
data have been processed by the master.
Only relevant in handshake mode (with
ACK).
Deletes decoding results that may have
been stored and resets the input data of
all modules.
Free
Free
Addr. Data type
0
UNSIGNED8 0: Without
Addr. Data
type
0.0
Bit
0.1
Bit
0.2
Bit
0.3
Bit
0.4
Bit
0.5
Bit
0.6
Bit
0.7
Bit
BCL 248i
Value
Default
range
0
ACK
1: With
ACK
Value range
Initial
value
1 > 0: Reading
0
gate off
0 > 1: Reading
gate active
0
0
0
0 > 1: Data has
0
been processed
by the master
1 > 0: Data has
been processed
by the master
0 > 1: Data reset 0