Leuze electronic BCL 248i Operating Instructions Manual page 129

Bar code reader
Table of Contents

Advertisement

Technical data
Electrical equipment
Supply voltage
Power consumption
VDE protection class
UL applications!
For UL applications, use is only permitted in Class 2 circuits in accordance with the NEC (Na-
tional Electric Code).
NOTICE
Protective Extra Low Voltage (PELV)!
The device is designed in accordance with protection class III for supply with PELV (Protective
Extra-Low Voltage).
Display elements
LEDs
Mechanical data
Degree of protection
Connection type
Weight
Dimensions (H x W x D)
Housing
Environmental data
Ambient temperature
Operation
Storage
Relative humidity
Vibration
Shock
Continuous shock
Electromagnetic compatibility
Conformity, approvals
Conformity
Leuze electronic GmbH + Co. KG
CAUTION
18 ... 30 V DC (PELV, Class 2)
≤ 4 W
III
3 LEDs for power (PWR), bus state (NET) and link state (LINK)
IP65
Connected cable, 0.9 m, M12 connector, 5-pin
Connected cable, 0.7 m, M12 connector, 4-pin
400 g incl. cable
38 x 92 x 83 mm (without cable)
Diecast aluminum
0 C ... +40 °C
-20 °C ... +70 °C
Max. 90 % (non-condensing)
IEC 60068-2-6, test Fc
IEC 60068-2-27, test Ea
IEC 60068-2-29, test Eb
EN 61000-6-3:2007-01 + A1:2011-03/AC:2012-08
EN 61000-6-2:2005-08 + AC:2005-09
CE
BCL 248i