Example Configuration: Direct Activation Via The Switching Input; Task; Procedure - Leuze electronic BCL 248i Operating Instructions Manual

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
8.17

Example configuration: Direct activation via the switching input

8.17.1 Task

• Reading of a 12-digit bar code in 2/5 Interleaved format
• Direct activation of the BCL 248i via a photoelectric sensor
Code sample
Code 2/5 Interleaved 12 digits with check digit

8.17.2 Procedure

Hardware, connections
The following connections must have been established:
• Voltage supply (PWR)
• PROFINET-IO (HOST) In
• Photoelectric sensor at SWI1
Required modules
Include the following modules in your project:
• Module 1023 – Decoding result 12 bytes
Parameter settings of the "device parameters"
Tab. 8.54:
Device parameters for example configuration 2
Byte
1
4
Flow charts
Successful reading
SPS
Zeit
Interne Verarbeitung
Leuze electronic GmbH + Co. KG
Description
Code type 1
Number of digits 3
Lichtschranke
Lichtschranke von 0 → 1
M 1023 Bit 0.1 von 0 → 1
M 1023 Bit 0.2 = 0
M 1023 Byte 1 = Datenlänge
M 1023 Byte 2-12 Ergebnis
Lichtschranke von 1 → 0
BCL 248i
Default value
0
0
BCL 2x8i
Beschreibung
Die Lichtschranke wird unterbrochen.
Das Signal vom Schaltausgang der Lichtschranke
liegt am Schalteingang des Barcodelesers an und
aktiviert den Scanner.
Gelesene Barcodes werden vom Modul 1023
verarbeitet und übertragen:
Lesung abgeschlossen Bit 0.1 = 1 und Barcode
decodiert Bit 0.2 = 0.
Im Byte 1 wird die Datenlänge eingetragen, hier 11
dezimal. Das Decodierergebnis wird in den
folgenden 11 Bytes übertragen.
Interne Verarbeitung der Daten.
Der Strahl der Lichtschranke wird wieder frei und
setzt den Schalteingang des Barcodelesers auf 0.
Das deaktiviert den Scanner.
Change value to
01: 2/5 Interleaved
12
109

Advertisement

Table of Contents
loading