Leuze electronic BCL 248i Operating Instructions Manual page 25

Bar code reader
Table of Contents

Advertisement

Device description
When configuring a PROFINET-IO system, the assignment of the device names to the configured IO de-
vices creates a name-based relationship for the participating IO devices ("device naming"). Further infor-
mation see chapter 8.3.5 "Step 5 – Set device name – device naming".
Identification & Maintenance functions
The BCL 248i supports the base record I&M0:
Tab. 4.4:
Base record I&M0
Index
Contents
0
Header
10
MANUFACTURER_ID
12
ORDER_ID
32
SERIAL_NUMBER
48
HARDWARE_REVISION
50
SOFTWARE_REVISION
54
REVISION_COUNTER
56
PROFILE_ID
58
PROFILE_SPE-
CIFIC_TYPE
60
IM_VERSION
62
IM_SUPPORTED
The BCL 248i supports further protocols and services for communication:
• TCP/IP (Client / Server)
• UDP
• DCP
• ARP
• PING
Further information on commissioning: see chapter 7 "Starting up the device – Leuze webConfig tool"
Leuze electronic GmbH + Co. KG
Data type
Description
10 bytes
Manufacturer specific
UNSIGNED16
Leuze manufacturer ID (Leuze
PNO manufacturer ID)
ASCII string 20
Leuze order no.
bytes
ASCII string 16
Unique device serial number
bytes
UNSIGNED16
Hardware revision number, e.g.,
0 ... 65535
1x CHAR,
Software version number, e.g.,
3x UNSIGNED8
V130 corresponds to V1.3.0
UNSIGNED16
Is incremented when updating
individual modules. This function
is not supported.
UNSIGNED16
PROFIBUS application profile
number
UNSIGNED16
Information about subchannels
and submodules, not relevant
2x UNSIGNED8
Implemented I&M version V1.1
Bit[16]
Optional I&M records available
BCL 248i
Value
338
Device-de-
pendent
Device-de-
pendent
Device-de-
pendent
0
0x0000 (Non
Profile)
0x0003 (I/O
Module)
0x01, 0x01
0
25