Leuze electronic BCL 248i Operating Instructions Manual page 99

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
Parameter
Reference code
completeness
comparison
Parameter length
8 bytes
Input data
None
Output data
None
8.14.3 Module 83 – Reference code comparison pattern 1
PROFINET-IO module identifier
Module ID: 1083
Submodule ID: 1
Description
This module can be used to define the 1st comparison pattern
Parameter
Parameter
Code type com-
parison pattern 1
Leuze electronic GmbH + Co. KG
Description
If this parameter is set,
the basic condition for a
positive reference code
comparison is that all
mandatory bar codes
that are to be read within
a reading gate were ac-
tually read. If this condi-
tion is not satisfied, no
positive reference code
comparison is achieved.
Description
Specifies the type of the ref-
erence bar code.
Addr. Data type
7.0
Bit
Addr. Data type
0
UNSIGNED8 0: No code
BCL 248i
Value range
0: Completeness com-
parison switched off.
1: Completeness com-
parison switched on.
Value range
1: 2/5 Interleaved
2: Code39
3: Code32
6: UPC, UPCE
7: EAN8, EAN13
8: Code128
10: EAN Addendum
11: Codabar
12: Code93
13: GS1 DataBar
Omnidirectional
14: GS1 DataBar
Limited
15: GS1 DataBar
Omnidirectional Ex-
panded
Default
0
Default
0
99

Advertisement

Table of Contents
loading

Table of Contents