Module 31 – Reading gate number
PROFINET-IO module identifier
Module ID: 1031
Submodule ID: 1
Description
The module defines input data for the communication of the number of reading gates since system start.
Parameter
None
Input data
Tab. 8.17:
Input data for module 31
Input data
Reading gate
number
Input data length
2 byte consistent
Output data
None
8.8.5
Module 32 – Reading gate time
PROFINET-IO module identifier
Module ID: 1032
Submodule ID: 1
Description
This module returns the time between opening and closing of the last reading gate.
Parameter
None
Input data
Tab. 8.18:
Input data for module 32
Input data
Opening dura-
tion of the read-
ing gate
Leuze electronic GmbH + Co. KG
Description
The BCL 248i transmits the current read-
ing gate number. The reading gate num-
ber is initialized with the system start and
is then incremented continuously. At
65535, an overflow occurs and the
counter starts again from 0.
Description
Opening duration of the last
reading gate in ms.
Addr. Data type
0 ... 1 UN-
Addr. Data type
0 ... 1 UN-
SIGNED16
BCL 248i
Value
range
0 ... 6553
SIGNED16
5
Value range
0 ... 65535 ms
If the range is ex-
ceeded, the value re-
mains at 65535
Initial
value
0
Initial
value
0 ms