Module 101 - Multiscan Slave Addresses 1 - Leuze electronic BCL 248i Operating Instructions Manual

Bar code reader
Table of Contents

Advertisement

Starting up the device - Configuration
Slave status
For each slave participant, one bit signals the network status of the respective slave.
• Value = 0: status "not ready"
• Value = 1: status "ready"
Input data length
1 byte
Output data
None
NOTICE
The presence of this module activates the multiScan master mode and sets all necessary mas-
ter communication parameters. In this case, the master IP address corresponds to the
PROFINET-IO device, i.e., its own IP address.
Data format of the IP_ADDRESS
The IP address is entered as a string in the usual IP-V4 notation, e.g., 192.168.0.1. In addition, it is permis-
sible to enter a 0 for the default setting.
IP_ADDRESS = 0 means that the node is deactivated, i.e., the entry is ignored. The slave enable parame-
ter is automatically set according to the IP address setting during the PNIO configuration phase.
8.15.5 Module 101 – multiScan slave addresses 1
PROFINET-IO module identifier
Module ID: 1101
Submodule ID: 1
Description
Additional module for the configuration of the slave addresses for slaves 11-20.
Parameter
Tab. 8.53:
Parameters for module 101
Parameter
multiScan slave
node 11
multiScan slave
node 12
multiScan slave
node 13
multiScan slave
node 14
multiScan slave
node 15
multiScan slave
node 16
multiScan slave
node 17
multiScan slave
node 18
multiScan slave
node 19
Leuze electronic GmbH + Co. KG
Description
IP address node 11
IP address node 12
IP address node 13
IP address node 14
IP address node 15
IP address node 16
IP address node 17
IP address node 18
IP address node 19
Addr. Data type
0
IP_ADDRESS
15
IP_ADDRESS
30
IP_ADDRESS
45
IP_ADDRESS
60
IP_ADDRESS
75
IP_ADDRESS
90
IP_ADDRESS
105
IP_ADDRESS
120
IP_ADDRESS
BCL 248i
Value range
Default
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
0.0.0.0
106