Starting up the device - Configuration
Parameter
Start position of
the 1st data
value
Start position of
the 2nd identi-
fier
Start position of
the 2nd data
value
Start position of
the 3rd identifier
Start position of
the 3rd data
value
Start position of
the 4th identifier
Start position of
the 4th data
value
Start position of
the 5th identifier
Start position of
the 5th data
value
Leuze electronic GmbH + Co. KG
Description
Specifies the position of the first
character of the first data value in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
Specifies the position of the first
character of the second identifier
in the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
Specifies the position of the first
character of the second data
value in the data string of the bar
code. The first character in the bar
code has position 1. If the param-
eter is = 0, it is deactivated.
Specifies the position of the first
character of the third identifier in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
Specifies the position of the first
character of the third data value in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
Specifies the position of the first
character of the fourth identifier in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
Specifies the position of the first
character of the fourth data value
in the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
Specifies the position of the first
character of the fifth identifier in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
Specifies the position of the first
character of the fifth data value in
the data string of the bar code.
The first character in the bar code
has position 1. If the parameter is
= 0, it is deactivated.
Addr. Data type
28
UNSIGNED8 0 ... 127
29
UNSIGNED8 0 ... 127
30
UNSIGNED8 0 ... 127
31
UNSIGNED8 0 ... 127
32
UNSIGNED8 0 ... 127
33
UNSIGNED8 0 ... 127
34
UNSIGNED8 0 ... 127
35
UNSIGNED8 0 ... 127
36
UNSIGNED8 0 ... 127
BCL 248i
Value range
Default
0
0
0
0
0
0
0
0
0
80